background image

SIZE: 380 mm x 152 mm • COLOR: HKS 92

For Removal of AutoMatrix

®

 Bands

Zur Entfernung von AutoMatrix

®

 Matritzenbändern

Pour le retrait des bandes AutoMatrix

®

Per la rimozione delle matrici AutoMatrix

®

Para retirar las bandas AutoMatrix

®

AutoMatrix

®

Snippers

+

K100404-00

If you have any questions, please contact

Für Rückfragen stehen wir Ihnen gerne zur 
Verfügung

Pour plus de renseignements, veuillez contacter

Per qualsiasi ulteriore informazione, contattare

Si tiene alguna pregunta, por favor contacte con

Если у Вас есть вопросы, пожалуйста, 
обращайтесь

Se desejar mais informação, é favor contactar

Om du har några frågor, vänligen kontakta

Gelieve voor al uw vragen contact op te nemen 
met

W razie pytań prosimy o bezpośredni kontakt

Hvis De har spørgsmål, kontakt da venligst

Για οποιεσδήποτε ερωτήσεις παρακαλούμε 

απευθυνθείτε

Máte-li jakékoli dotazy, prosím kontaktujte

Ak máte akékolvek otázky, prosím kontaktujte

Kérdésével kérjük forduljon az alábbi cimekhez

Sorunuz varsa, lütfen bizim ile temasa geçiniz

Ved spørsmål, ta kontakt med

Scientifc Service:
DENTSPLY 

D

e

T

rey

 GmbH

Phone: 

+

49 (0)7531 583-333

[email protected]

Distributor in the United Kingdom,  
Central & Eastern Europe:
DENTSPLY Limited
(UK) International Division
Building 3
The Heights, Brooklands
Weybridge, Surrey KT13 ONY
Phone: 

+

44 (0)19 32 85 34 22

Distributeur en France:
DENTSPLY France
Z.A. du Pas du Lac
4, rue M. Faraday
78180 Montigny-le-Bretonneux
Tél.: 

+

33 (0)1 30 14 77 77

Distributore in Italia:
DENTSPLY Italia S.r.l.
Piazza dell’Indipendenza, n° 11/B
00185 Roma
Tel.: 

+

39 06 72 64 03-1

Manufactured by 

DENTSPLY 

D

e

T

rey

 GmbH

De-Trey-Str. 1
78467 Konstanz
GERMANY
www.dentsply.eu

See webpage to view or print the instructions for use or to get a 

free print version.

Siehe Internetseite, um die Gebrauchsanweisung einpusehen oder auspudrucken 

oder ein kostenfreies gedrucktes Exemplar pu erhalten.
Se connecter à la page Web pour afcher ou imprimer les instructions d‘utilisation 

ou pour obtenir gratuitement une version imprimée.
Consultare il sito web per vedere o stampare le istrupioni per l’uso o per richiede-

re una stampa in omaggio.
Por favor, visite nuestra página web para ver y/o imprimir las instrucciones de 

uso, ó para obtener una copia de impresión gratuita.
Пройдите на веб-сайт для просмотра и печати инструкции по применению 

или получения бесплатной версии для печати.
Consulte a página web para ver ou imprimir as instruçoes de uso, ou para obter 

uma versao de impressao gratuita.
För att ta del av bruksanvisningen, för att skriva ut den eller för att erhålla ett tryckt 

exemplar utan kostnad, se hemsidan.
Raadpleeg de website om de gebruiksaanwijping te bekijken of te printen of voor 

een gratis printversie.
Zobacp stronę internetową, aby wyświetlić lub wydrukować instrukcje użytkowa-

nia lub upyskać beppłatną wersję do druku.
Se hjemmesiden for at se eller printe brugsanvisninger eller for at få en gratis print-

version.
Παρακαλούμε απευθυνθείτε στην ιστοσελίδα για να διαβάσετε ή τυπώσετε τις οδηγί-

ες χρήσης ή για να λάβετε ένα δωρεάν αντίτυπο.
Navštivte webovou stránku ke čtení nebo vytištění návodu k použití nebo k píská-

ní volné tiskové verpe.
Navštívte webovú stránku k prečítaniu alebo vytlačeniu návodu na použitie alebo 

k pískaniu voľnej tlačovej verpie.
A haspnálati utasítás megtekintéséhep vagy nyomtatásáhop, illetve egy nyomtatott 

példány igényléséhep keresse fel a honlapot.
Kullanım kılavupunu incelemek veya ücretsip indirmek veya ücretsip yapıcıdan çıktı 

almak için websitesini piyaret edinip.
Se nettsiden for å se eller printe ut bruksanvisningen eller laste ned en gratis ut-

skriftsversjon.

www.dentsply.eu/IFU

Cover-Layout-3.indd   1

13.08.14   14:51

Summary of Contents for AutoMatrix Snippers+

Page 1: ...ebpage to view or print the instructions for use or to get a free print version Siehe Internetseite um die Gebrauchsanweisung einpusehen oder auspudrucken oder ein kostenfreies gedrucktes Exemplar pu...

Page 2: ...y and Snippers Gap leads to malfunction of the Snippers and Catch Tray cannot prevent clipped loop pieces from the oral cavity 1 2 3 4 AutoMatrix Snippers Catch Tray Illustrated Technique Guide Attach...

Page 3: ...Mode d emploi__________________________________________________ 10 Istruzioni per l uso_______________________________________________ 14 Instrucciones de uso ________________________________________...

Page 4: ...l of AutoMatrix System bands by clipping of the projecting end of the Auto Lock loop The AutoMatrix Snippers consist of a stainless steel scissor like Snipper and a small Catch Tray to prevent clipped...

Page 5: ...ucts inconsistent with these Instructions for Use is at the discre tion and sole responsibility of the dental practitioner AutoMatrix Snippers should be cleaned and disinfected according to the proce...

Page 6: ...y or lingually while removing matrix occlusally 9 Properly discard matrix 10 Empty Catch Tray The Snippers can be reprocessed for up to 800 times The Catch Tray can be reprocessed for up to 80 times 4...

Page 7: ...g water 2 After opening place devices in the washer disinfector allowing water and detergent to wet all device surfaces and to drain off afterwards during the washer disinfector program Follow washer...

Page 8: ...x Snippers ist ein Instrument zur Entfernung von AutoMatrix Matritzen b ndern indem das herausstehende Ende der Auto Lock Schlinge abgetrennt wird Der AutoMatrix Snippers besteht aus einer aus rostfre...

Page 9: ...befestigt ist Drehen Sie die Kneifzange und berpr fen Sie dass keine L cke zwischen Auffangk rbchen und Kneifzange besteht Abbildungen 2 3 und 4 Stellen Sie sicher dass das Auffangk rbchen leer ist En...

Page 10: ...alls sich dieses Segment der AUTO LOCK METALLSCHLAUFE vom Matritzenband gel st hat entfer nen Sie es aus der Mundh hle und entsorgen Sie es entsprechend L cke zwischen Auffangk rbchen und Kneifzange b...

Page 11: ...Alternative zu manueller Reinigung und Desinfektion kann die Kneifzange auch in einem Thermodesinfektor 1 behandelt werden Nur einen korrekt gewarteten kalibrier ten und nach ISO 15883 1 zugelassenen...

Page 12: ...uit AutoMatrix Snippers est un instrument pour le retrait des bandes AutoMatrix qui sert couper l extr mit de la boucle auto bloquante AutoMatrix Snippers est constitu d un ciseau en acier et d un r s...

Page 13: ...que le r servoir est correctement connect l instrument Tourner l instrument et v rifer qu il n y ait pas d espace entre le r ser voir et l instrument fg 2 3 et 4 S assurer que le r servoir soit vide...

Page 14: ...tion de nettoyage l aide d un chiffon imbib d eau 6 S cher le dispositif avec un chiffon non pelucheux usage unique BOUCLE AUTO BLOQUANTE Localiser le segment gingival de la BOUCLE AUTO BLOQUANTE Cett...

Page 15: ...ouverture placer le dispositif dans un nettoyeur d sinfecteur autorisant l eau et les d tergents pour mouiller toutes les surfaces du dispositif et g rer l vacuation durant le programme du nettoyeur...

Page 16: ...rix Snippers uno strumento per la rimozione delle matrici AutoMatrix tramite il taglio dell estremit sporgente dell anello Auto Lock L AutoMatrix Snippers si compone di una forbice in acciaio inossida...

Page 17: ...gato corret tamente alla Snippers Girare lo strumento e controllare che non ci sia spazio tra il raccoglitore e la Snippers Fig 2 3 e 4 Accertarsi che il raccoglitore sia vuoto Dopo aver tagliato recu...

Page 18: ...i prodotti riutilizzabili descritto qui di seguito ANELLO AUTO LOCK Individuare il segmento gengivale dell ANELLO AUTO LOCK Questa parte di solito rimanere attaccata alla matrice al momento della rimo...

Page 19: ...del dispositivo rimuovere lo sporco utilizzando una spu gna morbida e acqua corrente 2 Dopo averlo aperto posizionare il dispositivo nel disinfettore in modo tale da per mettere all acqua ed al deter...

Page 20: ...matrix es un aditamento para retirar las bandas matrices cor tando en el extremo del circulo del bloqueo autom tico El Snippers de AutoMatrix es una tijera de acero inoxidable que incorpora una ban de...

Page 21: ...x antes de usarla Gire el instrument y asegurese que no hay ning n espacio entre la bandeja y el Snippers Fig 2 3 y 4 La bandeja de recogida debe de estar limpia Despu s de cortar retire de inmediato...

Page 22: ...a de las juntas y las inserciones del dispositivo 5 Elimine los restos de la soluci n de limpieza con un pa o empapado con agua 6 Sequelo el dispositivo con un pa o desechable que no suelte pelusa LOO...

Page 23: ...agua corriente para limpiarlo 2 Despu s de abierto coloque el dispositivo en la bandeja con desinfectante per mitiendo que el jabon y el detergente humedezca todas las superfcies y seque posterioremen...