REMOVAL OF HMI
INSTALLATION & REMOVAL
42
Figure 3
Figure 4
Loosening HMI fasteners.
Installation fasteners removed.
With the HMI free from all electrical wiring,
use a small flat head screwdriver to begin
loosening the 10 installation fasteners that
secure the HMI to the control enclosure door.
Make sure to support the HMI with the other
hand.
Continue to loosen fasteners until they can be
removed from the HMI.