![Dentech AYRDYNE 4.0 Installation, Operation And Maintenance Manual Download Page 33](http://html1.mh-extra.com/html/dentech/ayrdyne-4-0/ayrdyne-4-0_installation-operation-and-maintenance-manual_2483474033.webp)
www.ayrdyne.com
CONFIGURE
This button will re-download configuration.
This does not reset all parameters to
factory default. Consult the VFD manual for
instructions on how to reset all parameters
to factory default. After resetting to factory
default, make sure to press configure
button to download parameters needed for
operation of the drive. Button must be held
for 3 seconds. Indicators on the button will
turn blue once operation is complete.
MOTOR NOMINAL CURRENT (A)
This numeric entry/display shows the
motor full load amperage. Set to the motor
nameplate rated full load amps.
MOTOR NOMINAL VOLTS (VAC)
This numeric entry/display shows the motor
voltage. Set to the motor nameplate rated
volts.
AIRFLOW
31
DC LINK VOLTS (VDC)
This numeric display shows the VFD DC Bus
voltage.
OUTPUT FREQUENCY (Hertz)
This numeric display shows VFD output
frequency.
OUTPUT CURRENT (A)
This numeric display shows VFD output
current in amps.
ACTIVE FAULT
This text display shows the current status of
the VFD. If faulted, a fault code will be shown.
RESET
This button will reset VFD faults.
ACCELERATION RATE (s)
This numeric entry/display shows the
acceleration time in seconds. This value is
adjustable between 1s and 500s. Factory
default setting will vary with size of motor.
DECELERATION RATE (s)
This numeric entry/display shows the
deceleration time in seconds. This value is
adjustable between 1s and 500s. Factory
default setting will vary with size of motor.
PARAMETER NUMBER
This numeric entry/display shows which
parameter to view or edit.
PARAMETER VALUE
This numeric entry/display shows the value
of the parameter selected to view or edit.
Use caution when modifying parameters as it
may render the drive unusable.
1
2
4
3
6
5
8
7
9
2.3
10
11
12
OPERATION
Summary of Contents for AYRDYNE 4.0
Page 1: ...www ayrdyne com Installation Operation and Maintenance Manual 4 0 ...
Page 6: ...4 www ayrdyne com ...
Page 10: ...www ayrdyne com SYSTEM 8 2 1 3 MAIN SCREEN OVERVIEW 2 1 OPERATION 9 8 7 10 1 3 2 4 5 6 ...
Page 16: ...www ayrdyne com SYSTEM 14 2 1 6 SETTINGS USERS 2 1 OPERATION 1a 2 3 ci cii ciii 1b 1c 1d ...
Page 18: ...www ayrdyne com SYSTEM 16 2 1 7 SETTINGS I O 2 1 OPERATION 1 3 2 ...
Page 20: ...18 www ayrdyne com SYSTEM 2 1 OPERATION 2 1 8 SETTINGS DEVICES 5 6 7 2 3 4 1 ...
Page 22: ...www ayrdyne com FILTERS 20 2 2 1 PRIMARY INFO 2 2 OPERATION 6 1 7 8 9 2 3 4 5 ...
Page 24: ...www ayrdyne com FILTERS 22 2 2 2 PRIMARY SETTINGS 2 2 OPERATION 1 8 9 10 11 12 2 3 4 5 6 7 ...
Page 32: ...www ayrdyne com AIRFLOW 30 2 3 3 VFD SETTINGS 2 3 OPERATION 6 7 8 5 9 10 1 11 2 12 3 4 ...
Page 34: ...www ayrdyne com DISCHARGE 32 2 4 1 ROTARY VALVE IF EQUIPPED 2 4 OPERATION 1 4 2 3 5 6 ...
Page 49: ...47 www ayrdyne com NOTES ...