36
9.2 Communication
format
!
Data transmission format
Select one of the following two data transmission formats.
No. of digits
Header Code ID mark
Prefix
n1
n2
n3
n4
Code data
Suffix
Terminator
BCC
No. of digits
Header
Prefix
Code ID mark
n1
n2
n3
n4
Code data
Suffix
Terminator
BCC
(1) Header/Terminator
The following choices are available.
RS-232C interface
Header:
None (default) or STX
Terminator: CR (default), LF, CR/LF or ETX
For details, refer to Chapter 11.
(2) Prefix/Suffix
A prefix or suffix consists of up to five ASCII characters (00h to FFh). You can set a prefix or suffix with the
configuration software. (Default: No prefix or suffix)
(3) BCC
The Block Character Check (BCC) exclusive-ORs all bits at the same bit level in characters following the header and
preceding the terminator in a transmission block to generate a horizontal parity byte to be transferred in a binary code. The
BCC can be enabled or disabled. If no header is prefixed, no BCC will be transferred.