![Denso GT10Q-HR User Manual Download Page 27](http://html1.mh-extra.com/html/denso/gt10q-hr/gt10q-hr_user-manual_2483239027.webp)
17
Example Code read: QR Code,
Transmission of code ID mark: Disable, Header: STX, Terminator: ETX,
Transmission of the number of digits: Disable, BCC: Disable, Prefix/Suffix: None
Extraction conditions
Data read
Data block numbers
Output data
1,23,456,7890
1, 2 and 3
[STX]1[ETX][STX]23[ETX][STX]456[ETX]
1,23,456,7890
3, 1 and 2
[STX]456[ETX][STX]1[ETX][STX]23[ETX]
1234567890 1
[STX]1234567890[ETX]
1,,23,456,789
0
2 and 5
[STX][ETX][STX]7890[ETX]
1,23,456,7890
5 Error
1,23,456,7890
4 and 5
Error
"Code type": QR Code
"Data transfer
regardless of error
result": Prohibit
1234567890
1 and 2
Error
1,23,456,7890
5 [STX]1,23,456,7890[ETX]
1,23,456,7890
4 and 5
[STX]1,23,456,7890[ETX]
"Code type": QR Code
"Data transfer
regardless of error
result": Permit
1234567890
1 and 2
[STX]1234567890[ETX]
"Code type": QR Code
"Data transfer
regardless of error
result": Prohibit
1,23,456,7890
Invalid if specified.
Error
"Code type": PDF
"Data transfer
regardless of error
result": Permit
1,23,456,7890
Invalid if specified.
[STX]1,23,456,7890[ETX]