19
Example Data read: (01)94901234567894(11)030808(13)030810(17)040208(17)040305
Code ID mark: Disable, Header: STX, Terminator: ETX, Transmission of the number of digits: Disable,
BCC: Disable, Prefix/Suffix: None
Extraction conditions
AIs specified
Delimiter
Output data
01,11,17 [STX]94901234567894,030808,040208[ETX]
17,11 [STX]040208,030808[ETX]
17,17 [STX]040208,040305[ETX]
12 Error
01,12 Error
01,01 Error
"Data transfer
regardless of error
result": Prohibit
01,11,17 [STX]94901234567894,030808,040208[ETX]
17,11 [STX]040208,030808[ETX]
17,17 [STX]040208,040305[ETX]
12
01,12
"Data transfer
regardless of error
result": Permit
01,01
Comma
[STX]0194901234567894110308081303081017
04020817040305[ETX]
(Note 1) Element strings will be output in the order of AIs specified.
(Note 2) If data read contains two or more element strings prefixed with the same AI, those element strings will be output in
the order arranged in that data read.
(Note 3)
If data read does not contain a string prefixed with the specified AI or it contains such data but its number of digits is more or
less than the one defined for that AI,
an error will result when
the "Data transfer regardless of error result" is prohibited
.