Control element
U=displays the voltage
I = displays the amperage
F = displays the frequency
P = displays the output
Oil = displays the oil level
Time = displays the running
time
Over = displays an overload
SELECTOR SWITCH GAS SAVING MODE
The generator switches to fuel saving mode when connected consumers are turned off. When the
consumer is turned back on, the generator returns to the needed performance. With the selector
switch fuel consumption can be restricted and noise can be reduced if no performance is needed.
Attention!
The fuel saving mode is not adequate for use if the operator needs energy very quickly.
If several consumers with high power need are connected, turn off the selector switch fuel
saving mode in order to eliminate voltage fluctuation.
Turn off the selector switch fuel saving mode if the generator is constantly running on rated
power.
Solely protection switches that are made specifically for the generator offer effective protection
against electric shock. Pay attention to equal rated power and performance characteristics
when replacing the protection switches.
Due to the high mechanical strain, only resilient flexible cables with rubber jacket or similar
materials should be used (acc. to IEC 245-4).
Grounding
clamp
Ignition lock
Switch
fuel saving mode
Oil lack display
Operating display
AC-power-outlet
DC-power-outlet
DC reset
Fuel tap
Activation
of the remote
control
Emergency stop