b) If you started via remote control you can turn off the generator by pushing the
following button . Instead you can also switch the „Remote Control“ – button to
position „OFF“.
3. Close fuel tap / set it on position "OFF".
Attention!
Ensure that the cap of the fuel tank is closed and the ignition key is on position "STOP" for
shut down, transport and storage.
10. Maintenance
ATTENTION! Unplug the ignition coil before maintenance.
Good maintenance of your generator ensures safe, economical and smooth operation. Air pollution is
also reduced.
WARNING!
Turn off the generator prior to maintenance.
NOTICE
Use only original for replacement of defective or worn components in order to avoid damage
to the generator.
Maintenance plan
Regular maintenance at the
stated times or after according
hours of operation (choose earlier
date)
Before every
use
Monthly or
every 20
hours
Every 3
months or
every 50
hours
Every 6
months or
every 100
hours
Yearly or every
300 hours
Maintenance item
Engine oil
check
O
change
first time
O
air cleaner
check
O
clean
O
change
spark plug
clean
first time
O
replace
Visual inspection of generator
O
valve play
check - adjust
X
Cylinder head
clean
X
Throttle of
carburator
Check -
adjust
X
silencer screen
check
O
clean
O
Maintenance marked with “O” and "X" are compulsory Attention: Maintenance marked with "X" has to