in case of overload it will be indicated by the command
OVER
in the field
P
of the operating
display
in case of overload turn the ignition key into position "STOP" and remove connected devices
afterwards restart the generator
Attention!
If this happens, reduce the electric power you are taking from the generator or remove any
defective connected appliances.
Overload or malfunction of the consumers
Attention!
Inductive consumers require more power for start-up. So ensure that you don’t exceed the
rated power with the consumer you use..
Inductive consumers
(certain devices which are powered by an electric engine, e.g. drill hammers,
circular saws, chainsaws, compressors and pumps)
are consumers, which can only provide c. 70% of
their input power as output power on account of winding and friction losses. In addition, the engine
needs power for starting up, which is three to six times as high as the power rating of the device,
depending on model and quality of the engine. In case of doubt, we recommend a generator with
larger capacity, especially if the devices to be connected are of old design or engines with low
efficiency, which need higher-than-average starting currents.
12 V DC connector
If an overload occurs, the 12 V DC connector will be cut off. The 12 V DC connector can be
reconnected by pressing the overload switch (DC-Reset).
Attention!
The 12 V DC socket can only be charged with 100 W max.
Connecting to earth
The housing is allowed to be connected to earth in order to discharge static electricity. To do this,
connect one end of a cable to the earth connection on the generator and the other end to an external
earth (for example an earthing rod).
Grounding