JIG FOR SERVICING
Use the following jigs (extension cable kit) when repairing the PCBs.
Order with your dealer for the jigs your dealer if necessary.
CAUTION : Incorrect connections may cause malfunction.
Connection of Jig for DIGITAL PCB
---Items to Be Prepared---
8U-110084S : EXTENSION UNIT KIT
:
1 Set
Insulation sheet (Not supplied)
:
2 sheet
Ground lead (Not supplied)
:
2 pc
-Proceeding-
(1) Remove the screws.
(2) Remove the connector PCB.
↑
Shooting direction: A
↑
x26
x13
x2
x2 E3 ONLY
N1039
N1014
N1016
N1020
(3) Remove the DIGITAL PCB from the chassis and turn it over.
Place an insulation sheet larger than the PCB underneath the DIGITAL PCB.
b
Connect the earth of the PCB to the chassis using an earth wire, etc.
N5000
CN5003
PCB VIDEO
PCB DIGITAL
Insulation sheet
CHASSIS-HDMI CONNECTOR
CHASSIS-COMPOSITE CONNECTOR
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
161