Error
Code
Details of Error code
Display
Coping strategies
39
Connection to DPMS has timed
out when rewriting the Main CPU.
C o n n e c t i o n F a i l 3 9
Check the network connection. Update
in an environment where there is a
small network load.
3A
Error (NG) notification was re
-
ceived when downloading firm
-
ware for rewriting the Main CPU.
D o w n l o a d
f a i l
3 A
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
3B
Error notification (line congestion)
was received when downloading
firmware for rewriting the Main
CPU.
D o w n l o a d
f a i l
3 B
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
3C
Error notification (connection
failure) was received when down-
loading firmware for rewriting the
Main CPU.
D o w n l o a d
f a i l
3 C
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
3D
Failed to acquire the IP address
(Auto IP) before CX870 rewrite
(Boot Loader Mode).
C o n n e c t i o n F a i l 3 D
Check the network connection. Update
in an environment where there is a
small network load.
3E
Failed to acquire the IP address
before CX870 rewrite (Boot
Loader Mode) (timed out).
C o n n e c t i o n F a i l 3 E
Check the network connection. Update
in an environment where there is a
small network load.
50
Log in to DPMS failed when rewrit-
ing the DSP, PLD etc. firmware.
L o g i n
f a i l e d
5 0
Update in an environment where there
is a small network load.
51
Unit logs in to DPMS to rewrite the
DSP, PLD etc. firmware, but the
line etc. is congested.
S e r v e r
i s
b u s y 5 1
Update in an environment where there
is a small network load.
52
Connect to DPMS failed when
rewriting the DSP, PLD etc. firm
-
ware.
C o n n e c t i o n F a i l 5 2
Check the network connection. Update
in an environment where there is a
small network load.
54
Unit logs in to DPMS to rewrite the
DSP, PLD etc. firmware, but error
was received as firmware informa
-
tion.
U p d a t i n g
f a i l
5 4
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
55
Unit logs in to DPMS to rewrite
the DSP, PLD etc. firmware, but
logged into DPMS and requested
firmware data information but a
timeout occurred.
U p d a t i n g
f a i l
5 5
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
56
Unit logs in to DPMS to rewrite the
DSP, DLP etc. firmware, but failed
to download the firmware.
D o w n l o a d
f a i l
5 6
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
57
Unit logs in to DPMS to rewrite
the DSP, DLP etc. firmware, but
download firmware error was
received (line congestion).
D o w n l o a d
f a i l
5 7
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
58
Unit logs in to DPMS to rewrite
the DSP, DLP etc. firmware, but
download firmware error was
received (connection failure).
D o w n l o a d
f a i l
5 8
Turn on the power again. Update will
start automatically.
Update in an environment where there
is a small network load.
5A
NACK was received when "C"
command was sent to DSP, PLD
etc.
C o n n e c t i o n F a i l 5 A
Turn on the power again. Update will
start automatically.
5B
NACK was received when "L"
command was sent to DSP, PLD
etc.
U p d a t i n g
f a i l
5 B
Turn on the power again. Update will
start automatically.
72
All manuals and user guides at all-guides.com
Summary of Contents for AVR-S900W
Page 8: ...Personal notes 8 All manuals and user guides at all guides com...
Page 27: ...Personal notes 27 All manuals and user guides at all guides com...
Page 144: ...Personal notes Personal notes 144 All manuals and user guides at all guides com...
Page 166: ...ANODE CONNECTION 166 All manuals and user guides at all guides com a l l g u i d e s c o m...