Maintenance 

The 

 skimmer range should require very little adjustment and maintenance. Due to the high levels of calcium in marine aquariums and large volumes 

of  air  drawn in, it is  common  for  deposits  to  accumulate. Regular introduction  of  a  small  amount  of RO  water into the inlet tap  whilst  running may  help  to 
prevent any build up of salt and debris in the venturi.  

 

 

 

 

Fault finding 

 

Malfunction 

cause 

remedy 

 

 

 

Pump produces 

insufficient air 

tap, airline or venturi blocked 

clean 

airline kinked 

remove kink 

ozonizer blocked 

clean 

 

 

 

excessive air bubbles in 

aquarium water, often in 
new installations 

caused by additives in certain 
sea salts and water conditioners 

use different salt or feed heavily for a 
period, empty skimmer cup frequently, 
open air tap fully or remove for a few days. 
This condition may last for several weeks.  

air tap closed to far 

open air tap 

 

Technical data 

Dimensions 

(l/w/h) app. 

Power 

consumption 

Air flow app. 

min. height for 

sump installation 

Aquarium size 

normal stocking 

Aquarium size 

light stocking 

MCE 400 

216x77x490mm 

9 Watt 

350 ltr./h 

600mm 

400 ltr. 

500 ltr. 

 
 
 
 

 

 
 

 
 

 

 
 

 
 

 

 
 

 
 

 

Summary of Contents for MCE 400

Page 1: ...MCE 400 Bedienungsanleitung und Ersatzteilliste Operating instruction and Spare parts list...

Page 2: ...Ber hrung kommen Wenn der Stecker oder die Steckdose nass wird NICHT das Kabel herausziehen sondern die Stromversorgung an der Sicherung bzw am Leistungsschalter trennen Dann erst den Stecker herausz...

Page 3: ...eingeschoben werden Die Trennplatte Nr 14 muss dabei nach unten gedr ckt werden Einstellung Die richtige Einstellung kann erst nach dem Einlaufen 24 Stunden erfolgen Bis dahin den Schaumtopf nicht we...

Page 4: ...n Fehlersuche Symptom Ursache Ma nahme Pumpe l uft jedoch keine oder zu geringe Luftmenge Absperrhahn Lufteinzugsd se oder Luftzuleitung zur Pumpe verstopft reinigen Ozonger t verschmutzt reinigen Luf...

Page 5: ...and coming in contact with the receptacle If the plug or socket does get wet DON T unplug the cord Disconnect the fuse or circuit breaker that supplies power to the appliance Then unplug and examine...

Page 6: ...p after a short while the pump and the suction pipe will be bled of all air Open the air tap The skimmer is now ready for operation Make sure that both silicone hoses are not blocked or kinked Please...

Page 7: ...tap airline or venturi blocked clean airline kinked remove kink ozonizer blocked clean excessive air bubbles in aquarium water often in new installations caused by additives in certain sea salts and...

Page 8: ...ourra pas entrer en contact avec celui ci Si la fiche ou la prise de courant se mouille NE PAS retirer le c ble mais couper l alimentation en courant au fusible ou au sectionneur de puissance Ne retir...

Page 9: ...ration dans le corps de l cumeur Fermez le robinet d air Replacez le pot de l cumeur 50m de profondeur Branchez la pompe peu apr s le la pompe et le tuyau d aspiration seront purg s de tout l air Ouvr...

Page 10: ...e par osmose inverse dans le robinet d aspiration d air lorsque l cumeur est en fonction Diagnostic D faut Cause Rem de Pompe produit insuffisament d air Robinet la ligne d air ou le venture est encr...

Page 11: ...i collegamento nel caso si usi una prolunga impedendo cos che l acqua gocciolando lungo il cavo venga a contatto con la presa Se la presa o la spina si bagna NON disinserire il cavo ma scollegare l in...

Page 12: ...ar partire la pompa dopo poco pompa e tubo di aspirazione saranno privi di aria Aprire il rubinetto dell aria Lo schiumatoio adesso pronto per funzionare Controllare che ambedue i tubi in silicone non...

Page 13: ...deviato modificare il percorso del tubo La valvola di flusso 8a nella pompa ostruita Eseguire pulizia Forte presenza di bolle d aria nell acqua in entrata spesso in nuove installazioni Si nota in con...

Page 14: ......

Page 15: ...per DCS 400 9 28017100 Lager 3 teilig Bearings 3 pcs Palier 3 pcs 10 81140400 Pumpengeh use DCS 400 Pump housing DCS 400 Carter pompe DCS 400 Alloggiamento pompa DCS 400 11 69511000 O Ring UP 1000 O...

Page 16: ...Deltec GmbH Steller Stra e 75 D 27755 Delmenhorst Deutschland Germany www deltec aquaristic com Deltec GmbH...

Reviews: