background image

Revised 2020-06

USER MANUAL

 

UG110, UG110V, UG110VP

SPRAY GUN CLEANERS

UG110

WWW.UNIRAM.COM 

CORPORATION

 381 Bentley Street, Markham ON L3R 9T2

• Tel. 1-800-417-9133 
• [email protected]

Summary of Contents for UG110

Page 1: ...Revised 2020 06 USER MANUAL UG110 UG110V UG110VP SPRAY GUN CLEANERS UG110 WWW UNIRAM COM CORPORATION 381 Bentley Street Markham ON L3R 9T2 Tel 1 800 417 9133 sales uniram com...

Page 2: ...4 LOCATION 4 LEVELING MOISTURE FILTER AND AIR SUPPLY 4 SOLVENT SELECTION 5 SOLVENT PAIL SETUP 5 OPERATION 5 PRE CLEAN 5 CLEANING SPRAY GUNS AND CUPS 5 AFTER CLEANING 6 UG110VP ONLY 6 DAILY MAINTENANCE...

Page 3: ...3 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 UG110 Drain Hose rear Suction Hose Diaphragm Pump Drain Valve inside Timer Comercial Pail of solvent provided by the User Wash Tank inside...

Page 4: ...cover on the Air Input right side of machine and to ensure that the air supply is clean and dry attach an Airline Filter not supplied Attach an air supply adapter not supplied to the Airline Filter Th...

Page 5: ...lied Rinse cup with solvent and pour into the same 5 gallon pail for later disposal or recycling CLEANING SPRAY GUNS AND CUPS Loosen the air cap of the spray gun two full turns Lock the trigger in the...

Page 6: ...bottom of the tank and clean when necessary Drain and flush the Moisture Filter allowing air under pressure to flow through it REPLACING SOLVENT Close the Drain Valve under the unit Remove the Suction...

Page 7: ...ERATOR MAIN TAINS TANK Solvent lacks cleaning strength Replace solvent with solvent that is for mulated for type of paint used and for use with automatic spray gun cleaning GUNS NOT CLEAN PUMP WORKING...

Page 8: ...issing sound and the pump is not cycling the spool valve has stalled due to a blocked air passage Follow the pro cedure below to clear the blockage Connect a blow gun to an 60 PSI source Locate the bl...

Page 9: ...9 MANUAL UG110 SERIES GUN CLEANERS REVISED 2020 06 FLOW DIAGRAMS Use to trace the flow of compressed air and water...

Page 10: ...Holder 100 413F Mechanical Timer Assembly 5 minutes 115 200 K Trigger Clamp and Plug Kit 140 2341 Rotating Spray Jet 140 340S Ground Wire 18G Green 4 FT 100 835 Ground Wire Suction Tube 100 8335 Lid s...

Page 11: ...free of charge and arrange for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stor...

Reviews: