23
Quick installation guide for RPI M15A M20A inverters
Mechanical Design
RPI-M15A
RPI-M20A
Dimensions (W x H x D)
612 x 625 x 278 mm
Weight
43 kg
Cooling
Fans
AC Connector type
AC Plug Amphenol C16-3
DC Connector type
Multi-Contact MC4
Communication interfaces
2 x RS485, 1 x Dry contact, 1 x EPO
General Specification
RPI-M15A
RPI-M20A
Delta model name
RPI-M15A
RPI-M20A
Delta part number
RPI153FA0E0000
RPI203FA0E0000
Maximum efficiency
98 3%
98 4%
EU efficiency
97 9%
98 1%
Operating temperature range
-25 +60 °C
Operating temperature range without derating
-25 +40 °C
-25 +47 °C
4)
Storage temperature range
-25 +60 °C
Relative humidity
0 100 %, non-condensing
Maximum operating altitude
2000 m above sea level
Standards and Directives
RPI-M15A
RPI-M20A
Protection degree
IP65
Safety class
I
Pollution degree
II
Overload behavior
Current limitation; power limitation
Safety
IEC 62109-1 / -2, CE compliance
EMC
EN 61000-6-2, EN 61000-6-3
Immunity
IEC 61000-4-2 / -3 / -4 / -5 / -6 / -8
Harmonics
EN 61000-3-2
Variations and flicker
EN 61000-3-3
1)
IEC 60664-1, IEC 62109-1
2)
For cos phi = 1 (VA = W)
3)
AC voltage and frequency range will be programmed according to the individual country requirements.
4)
Derating starting at 47 °C with nominal DC voltage and AC output power of 21 kVA