11 Technical Data
11.1 Specifications
Model
RPI-H3
GENERAL
RPI-H5
Enclosure
Operating temperature
Relative humidity
Galvanic isolation
Safety class
Overvoltage category
Maximum input power
Normal voltage
Operating voltage range
Absolute maximum voltage
MPP range (rated power)
Rated power
Maximum power
3000 VA
3000 VA (#1)
5000 VA
5000 VA
13 A
14.3 A
21.7 A
24.5 A
97.00%
96.20%
97.50%
97.00%
Voltage
Rated current
Max. current
Frequency
Total harmonic distortion
Power factor
Peak efficiency
EU efficiency
/-20%
50/60 Hz
<3% with Rated power(#2)
>0.99@Rated power(#2)
Input connection
Startup voltage
MPPT tracker
Maximum input current
Powder-coated aluminium
-20~60°C, full power up to 40°C
Operating Altitude
2000m
0% – 95% non-condensing.
Environmental category
Outdoor, wet locations
NO
Class I metal enclosure with protective earth
Pollution degree
Internal: II, External: III
AC output: III, DC input: II
Flicker impedance
Z = 0.4 + j 0.25 Ω (total impedance)
Three-phase combinations
No
3200W
5425W
350 Vdc
650 Vdc
125~550 Vdc
200~1000 Vdc
600 Vdc
1000 Vdc
320~500 Vdc
310~850 Vdc
10 A
17.5 A
150 Vdc
250 Vdc
Maximum short circuit current
13.9 A
24.5 A
1
MC4, 2 pairs
DC INPUT (Solar side)
AC OUTPUT (Grid side)
54
Technical Data
Summary of Contents for RPI-H3
Page 2: ......
Page 12: ...Figure 2 3 The identification label for H5 RPI H5 12 Installation and Wiring...
Page 15: ...Figure 3 4 LCD display and buttons 3 2 1 LCD Display and Buttons 15 Product Overview...
Page 18: ...Figure 4 1 Screw the mounting bracket for RPI H3 18 Installation...
Page 19: ...Figure 4 2 Screw the mounting bracket for RPI H5 19 Installation...
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ...Version 04180115 5013208606...