15
・
Process the cables before use.
・
Creating 6-pin connectors
Hold down the enclosed 6-pin connector
①
, and insert the cable.
・
Connecting the main unit and the 6-pin connectors
(1)
Insert the 6-pin connector into the main unit.
(2)
Pass a screwdriver through the screw hole, and tighten the two screws for the 6-pin connector.
(3)
When all the wiring is complete, install the Power Monitor in its installation site.
When the connectors are complete, connect to the main unit.
8mm
Cable
40mm
Φ0.6~0.8
Φ5~6
①
Screw hole
Screw hole
■Under-wiring
■Over-wiring
3.2.Setting Power Monitor and Cable
Setting