PMT2 Panel Mount Power Supply 

PMT2 150W series / PMT-

V150W2C

□□

 

TECHNICAL DATASHEET

 

  

All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.

 

  www.DeltaPSU.com (September. 2022, Rev. 02)  

4

 

Safety Standards / Directives 

Safety Entry Low Voltage 

SELV 

Electrical Safety 

TUV Bauart 

cULus 

CB scheme 

CCC 

KC 

EAC 

BSMI 

EN 62368-1, EN 60335-1, EN 61558-1/-2-16 
UL 62368-1, and CAN/CSA C22.2 No. 62368-1 
IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 
GB 4943 (design compliance) 
K 60950-1 (12 & 24 V model)  
TP TC 004/2011 
CNS 14336-1 

CE 

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 

2014/35/EU 

UKCA 

In conformance with Electromagnetic Compatibility Regulations 2016 and 

Electrical Equipment (Safety) Regulations 2016 

Galvanic Isolation 

Input to Output  4.0 KVac 

Input to Ground  2.0 KVac 

Output to Ground  1.25 KVac 

EMC 

Emissions (CE & RE) 

CISPR 32, EN/ BS EN 55032, EN/ BS EN 61000-6-4, KN 32

AS/NZS 

CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/ BS EN 

61000-6-3 : Class B 

Immunity 

EN/ BS EN 55035, KN 35, EN/BS EN 61000-6-2 
Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-1 
 

Electrostatic Discharge 

IEC 61000-4-2  Level 4 Criteria A

1)

   

Air Discharge: 15kV 

Contact Discharge: 8kV  

Radiated Field 

IEC 61000-4-3  Level 3 Criteria A

1)

   

80 MHz-1 GHz, 10V/M with 1 kHz tone / 80% modulation 

Electrical Fast Transient / Burst 

IEC 61000-4-4  Level 3 Criteria A

1)

  

2 kV 

Surge 

IEC 61000-4-5  Level 4 Criteria A

1)

  

Common Mode

4)

: 4 kV 

Differential Mode

5)

: 2 kV 

Conducted 

IEC 61000-4-6  Level 3 Criteria A

1)

   

150 kHz-80 MHz, 10 Vrms 

Power Frequency Magnetic Fields 

IEC 61000-4-8  Level 4 Criteria A

1)

  

30 A / Meter  

Voltage Dips and Interruptions 

IEC 61000-4-11  0% residual; 1 cycle, Criteria B 

40% residual; 10 cycle, Criteria C

3)

 

70% residual; 25 cycle, Criteria C

3)

 

Harmonic Current Emission 

IEC

/

EN/BS EN 

61000-3-2 

Class A 

Voltage Sag Immunity SEMI F47 – 

0706 

80% of 200 Vac 
70% of 200 Vac 
50% of 200 Vac 

160 Vac, 1000 ms 
140 Vac, 500 ms  
100 Vac, 200 ms 

Criteria A

1)

 

Criteria A

1)

 

Criteria A

1)

 

1) Criteria A: Normal performance within the specification limits

2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.

3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)

4) Asymmetrical: Common mode (Line to earth)

5) Symmetrical: Differential mode (Line to line)

Summary of Contents for PMT-12V150W2C Series

Page 1: ...eneration PMT2 power supplies is designed in a low 30mm profile and accepts universal AC input The highly efficient convection cooling construction can operate from 30 C to 70 C The single output mode...

Page 2: ...Vdc 1 36 Vdc 1 48 Vdc 1 Output Voltage Adjustment Range 10 8 13 2 Vdc 13 5 16 5 Vdc 21 6 26 4 Vdc 27 0 33 0 Vdc 32 4 39 6 Vdc 43 2 52 8 Vdc Output Current 0 12 5 A 0 10 0 A 0 6 5 A 0 5 0 A 0 4 3 A 0 3...

Page 3: ...G for a duration of 11 ms 3 shocks for each 3 directions Operating IEC 60068 2 27 Half Sine Wave 10 G for a duration of 11 ms 3 shock for each 3 directions Vibration Non Operating IEC 60068 2 6 Rando...

Page 4: ...55014 2 EN BS EN 61000 6 1 Electrostatic Discharge IEC 61000 4 2 Level 4 Criteria A1 Air Discharge 15kV Contact Discharge 8kV Radiated Field IEC 61000 4 3 Level 3 Criteria A1 80 MHz 1 GHz 10V M with...

Page 5: ...EET All parameters are specified at 25 C ambient and nominal AC input unless otherwise indicated www DeltaPSU com September 2022 Rev 02 5 Block Diagram Device Descriptions 1 Input Output terminal bloc...

Page 6: ...l AC input unless otherwise indicated www DeltaPSU com September 2022 Rev 02 6 Dimensions L x W x H 159 x 97 x 30 mm 6 26 x 3 82 x 1 18 inch Wire AWG Table Current rating for PVC Wire AWG 6AWG 52 5A 2...

Page 7: ...mperature at 30 C 3 If the output capacity is not reduced when the surrounding air temperature 50 C the device will run into Over Temperature Protection When activated power supply will latch off unti...

Page 8: ...is surface belongs to customer s end system or panel where the power supply is mounted Connector Base Mounting Horizontal If the device has to be mounted in any other orientation please contact info d...

Page 9: ...e terminals while power is being supplied Risk of electric shock Prevent any foreign metal particles or conductors from entering the device through the openings during installation It may cause Electr...

Page 10: ...e specifications It is not recommended to prolong the duration of Io when it is 110 but 100 since it may cause damage to the PSU Short Circuit Protection Auto Recovery The power supply s output OLP OC...

Page 11: ...ion for any claim or action arising from any error for the provided information in the datasheets Customer shall take its responsibility for evaluation of using the product before placing an order wit...

Reviews: