PMT2 Panel Mount Power Supply
PMT2 150W series / PMT-
□
V150W2C
□□
TECHNICAL DATASHEET
All parameters are specified at 25°C ambient and nominal AC input unless otherwise indicated.
www.DeltaPSU.com (September. 2022, Rev. 02)
4
Safety Standards / Directives
Safety Entry Low Voltage
SELV
Electrical Safety
TUV Bauart
cULus
CB scheme
CCC
KC
EAC
BSMI
EN 62368-1, EN 60335-1, EN 61558-1/-2-16
UL 62368-1, and CAN/CSA C22.2 No. 62368-1
IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16
GB 4943 (design compliance)
K 60950-1 (12 & 24 V model)
TP TC 004/2011
CNS 14336-1
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive
2014/35/EU
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and
Electrical Equipment (Safety) Regulations 2016
Galvanic Isolation
Input to Output 4.0 KVac
Input to Ground 2.0 KVac
Output to Ground 1.25 KVac
EMC
Emissions (CE & RE)
CISPR 32, EN/ BS EN 55032, EN/ BS EN 61000-6-4, KN 32
,
AS/NZS
CISPR 32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/ BS EN
61000-6-3 : Class B
Immunity
EN/ BS EN 55035, KN 35, EN/BS EN 61000-6-2
Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-1
Electrostatic Discharge
IEC 61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field
IEC 61000-4-3 Level 3 Criteria A
1)
80 MHz-1 GHz, 10V/M with 1 kHz tone / 80% modulation
Electrical Fast Transient / Burst
IEC 61000-4-4 Level 3 Criteria A
1)
2 kV
Surge
IEC 61000-4-5 Level 4 Criteria A
1)
Common Mode
4)
: 4 kV
Differential Mode
5)
: 2 kV
Conducted
IEC 61000-4-6 Level 3 Criteria A
1)
150 kHz-80 MHz, 10 Vrms
Power Frequency Magnetic Fields
IEC 61000-4-8 Level 4 Criteria A
1)
30 A / Meter
Voltage Dips and Interruptions
IEC 61000-4-11 0% residual; 1 cycle, Criteria B
40% residual; 10 cycle, Criteria C
3)
70% residual; 25 cycle, Criteria C
3)
Harmonic Current Emission
IEC
/
EN/BS EN
61000-3-2
Class A
Voltage Sag Immunity SEMI F47 –
0706
80% of 200 Vac
70% of 200 Vac
50% of 200 Vac
160 Vac, 1000 ms
140 Vac, 500 ms
100 Vac, 200 ms
Criteria A
1)
Criteria A
1)
Criteria A
1)
1) Criteria A: Normal performance within the specification limits
2) Criteria B: Output out of regulation, or shuts down during test. Automatically restored to normal operation after test.
3) Criteria C: Output out of regulation, shuts down during test (Need to recycle AC power cord to normal operation after test)
4) Asymmetrical: Common mode (Line to earth)
5) Symmetrical: Differential mode (Line to line)