34
Installation and operation manual M70A_260 Flex RPI703M26000 EU V1.1 EN 2022-08-02
5 Planning the installation
Installation location
> 50
> 300
> 300
> 200
A
A
and air circulation
Fig. 5.6:
Mounting distances and air circulation, variant 3 (in mm)
► Ensure sufficient air circulation. There must not be heat
buildup around the inverter. For installation clearances of
30 to 60 cm between two inverters, install a separation
plate (A) between the inverters. This separation plate is
designed to prevent the right-hand inverter from sucking in
the warm air of the left-hand inverter. No separation plate is
required for clearances greater than 60 cm.
►
Observe
Operating temperature range without derating
the
Total operating temperature range
(see “14. Technical
When the
operating temperature range without derating
is
exceeded, the inverter reduces the AC power fed into the
grid.
When the
Total operating temperature range
is exceeded,
the inverter stops feeding AC power into the grid.
This is normal operating behavior for the inverter and is
necessary to protect the internal electronics.
►
Position multiple inverters so that they do not heat each
other up.
►
Observe the minimum bend radius of the cables used (es-
pecially the AC cable)!
► Ensure the accessibility of the side components (air filters,
fan module, AC cable gland, DC connector panel, etc.) for
maintenance and repair work.
►
Allow space to the front to open the door.
► In areas with many trees or fields, pollen and other parts of
plants can clog the air inlets and air outlets, obstructing the
air flow.
If there is a loss of performance during operation, clogged
air filters may be a cause (see chapter