165
Installation and operation manual M70A_260 Flex RPI703M26000 EU V1.1 EN 2022-08-02
14 Technical Data
Mechanical details
M70A
Dimensions (W x H x D)
699 × 629 × 264 mm
Weight
69 kg
Cooling
1x fan module containing 4x fans for circulating ambient air,
replaceable
2x internal fans for preventing heat buildup, replaceable
Mounting options
suspended (mounting plate included in the scope of delivery)
free-standing (mounting feet available as an accessory)
Communication and Data Visualization
M70A
Communication interfaces
2x RS485, 2x dry contacts, 1x EPO, 1x 12 V
DC
power supply, 6x
digital inputs
Communication
RS485, Sub-1G, Wi-Fi (optional)
Communication protocols
Modbus RTU
General specifications
M70A
Delta model name
M70A_260
Delta part number
RPI703M260000
Overall operating temperature range
-25 to +60 °C
Reltaive humidity
0 to 100%, non-condensing
Max. operating height
4000 m above sea level
Noise level
<67.5 dB(A)
Standards and guidelines
M70A
Protection degree
IP66
Safety class
II
Pollution degree
II
Overload behavior
Current limitation, power limitation
Safety
IEC 62109-1/-2, CE compliance
EMC
EN 61000-6-2/-6-3/-3-11/-3-12
Noise immunity
IEC 61000-4-2/-3/-4/-5/-6/-8
Distortion factor
EN 61000-3-2
Voltage fluctuations and flicker
EN 61000-3-3
Grid connection guidelines
You will find the current list at
1)
The maximum withstand voltage is 1100 V
DC
. The inverter starts to work if the input voltage falls below 1000 V
DC
.
2)
IEC 60664-1, IEC 62109-1
3)
For cos phi = 1 (VA = W)
4)
At ambient temperatures ≤ 40°C
5)
AC voltage and frequency range will be programmed according to the individual country requirements.
6)
Power consumption with standby communication