Step G
If the power supply is kept off for a while, please remove AC power cord.
Don’t touch the load before grounding it. And make sure the electricity is fully discharged by meter.
7.2.
D-sub Operating Steps
Example : CP mode 1.5 kW output
Operating steps:
1.
Set the front panel => Interface Setup => Communnication Setup => D-sub.
2.
Command Level: Set +10 V input to pin 5 for 1.5 kW Command.
3.
Enable On: Connect pin 4 to pin 9
4.
Enable Off: Remove pin4 from pin 9.
7.3.
RS-232 Operating Steps
1.
Set the front panel => Interface Setup => Communnication Setup => RS-232.
2.
Follow the protocol defined in chapter 6.4 to operating.
3.
Set Pulse reverse time and Pulse frequency
Remote to PSU
Byte
0
1
2
3
4
5
6
7
8
9
10
IP
Command
Data1
Data2
Check Sum
Termination
Byte
H-Byte
L-Byte
H-Byte L-Byte H-Byte L-Byte
0x00
Byte
0x00
0x0D
Pulse
reverse time
IP
0x29
0x00/01
0x00
0x00
Value
0x00
Value
0x00
0x0D
Pulse
frequency
IP
0x2A
0x00/01
0x00
0x00
Value
0x00
Value
0x00
0x0D
4.
Set Operating mode
Remote to PSU
Byte
0
1
2
3
4
5
6
7
8
9
10
IP
Command
Data1
Data2
Check Sum
Termination
Byte
H-Byte
L-Byte
H-Byte L-Byte H-Byte L-Byte
0x00
Byte
0x00
0x0D
CV Mode
IP
0x11
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
CC Mode
IP
0x12
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
CP Mode
IP
0x13
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
5.
Power on and power off