Load Cell Module DVP02LC-SL
DVP-PLC Operation Manual
13
bit15 ~ 2
bit7 ~ 4
bit3 ~ 0
CH2 CH1
Reserved
H’0 = gross weight
H’1 = net weight
H’F = channel disabled
C R # 8 , 9 :
CH1 to CH2 tare weight
Explanations:
You can write in the weight or read it by commands. Default: K0. Range: K-32,768 to K32,767.
C R # 1 0 , 11:
CH1 to CH2 average times
Explanations:
The range is 1 to 100. When the value exceeds 100, it will automatically be switched to 100. When it
falls below 1, it will automatically be switched to 1.
Range
Default
1
≤
average times
≤
100
10
C R # 1 2 , 13 :
CH1 to CH2 average weight
Explanations:
The average weight is displayed.
C R # 1 4 , 15 :
CH1 to CH2 present weight
Explanations:
The present weight is displayed.
C R # 1 6 , 17 :
CH1 to CH2 times of standstill check
Explanations:
Default: K5. Range: K1 to K500. See 5.3.2 for details.
C R # 1 8 , 19 :
CH1 to CH2 range for standstill check
Explanations:
Default: K10. Range: K1 to K10,000. See 5.3.2 for details.
C R # 2 0 , 21 :
CH1 to CH2 decimal point place
Explanations:
The place of the decimal point set up by the user.
Range
Default
0
≤
decimal point place
≤
4
2