- 11 -
Communication Parameter Setting
Content
0
1
2
3
4
5
6
Baudrate 2,400bps
4,800bps
9,600bps
19,200bps 38,400bps 57,600bps 115,200bps
Parity bit
None (N)
Even (E)
Odd (O)
Table 4
Error Codes
The error codes can be read from address H1000 ~ H1007. When the input operation is in normal status, H1000 ~ H1007 are for input values.
When input error occurs (except for stable status and input exceeding the range), DTE will read error codes in H8001 ~ H8002.
H1000 Error
description
H8001
EEPROM cannot be written in.
H8002
Input sensor is not connected.
H8003
Group INB is not connected.
Table 5
Analog output current tuning scale:
1
μ
A/scale
Analog output voltage tuning scale:
1mV/scale
Returning to Default Value:
Write H1234 into address H10F1 and H1357 into address H10F2. Restart DTE.
Programmable Communication Parameter Setting
INA
INB
Content
Explanation
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
Read remaining time of the step
Unit: sec
H111E
H121E
H131E
H141E
H151E
H161E
H171E
H181E
Read remaining time of the step
Unit: min
H111F
H121F
H131F
H141F
H151F
H161F
H171F
H181F
Read the NO. of the current
pattern
0 ~ 7
H1120
H1220
H1320
H1420
H1520
H1620
H1720
H1820
Read the NO. of the current step 0 ~ 7
H1121
H1221
H1321
H1421
H1521
H1621
H1721
H1821
NO. of start pattern
0 ~ 7
H1122
H1222
H1322
H1422
H1522
H1622
H1722
H1822
NO. of start step
0 ~ 7
H1123
H1223
H1323
H1423
H1523
H1623
H1723
H1823
Programmable Parameter Setting
Content
Explanation
Pattern 0 Pattern 1 Pattern 2 Pattern 3 Pattern 4 Pattern 5 Pattern 6 Pattern 7
Max. number of
steps in the pattern
0 ~ 7 = N: The pattern
executes from step 0 to
N.
H2068
H2069
H206A
H206B
H206C H206D H206E
H206F
Number of cycles of
pattern 0 ~ 7
execution
0 ~ 199: The pattern has
been executed for 1 ~
200 times
H2070
H2071
H2072
H2073
H2074
H2075 H2076
H2077
NO. of current link
pattern
0 ~ 8: 8 refers to end of
program; 0 ~ 7 refer to
the NO. of next pattern
H2078
H2079
H207A
H207B
H207C H207D H207E
H207F
Address
Default
Content
Explanation
2000H ~ 203FH
0
Target temperatures for pattern 0 ~ 7
Pattern 0: 2000H ~ 2007H
Unit: 0.1°C
2080H ~ 20BFH
0
Execution time for pattern 0 ~ 7
Pattern 0: 2080H ~ 2087H
Time: 0 ~ 900 (Unit: 1 min)
4. Communication format: H03 = read bit data; H06 = write bit data