User and Installation Manual for DE212-1S Wired Deadman
D
ELTA
RCS
AS
Page 4 of 17
Document: 02002
P3
Input Signals
1
Deadman Override
Active at low input, 0V
2
Not in use
(Do not connect)
3
External STOP
Active at low input, 0V
4
Deadman cable input (+5V)
5
Deadman cable input (0V)
NOTE: 0V is normally the same
Potential as chassis/GND
.
2.
I
NSTALLATION
2.1
C
ONTROL
U
NIT
,
CU212-1S
C
ONNECTIONS
The power supply can be 12 or 24VDC, and is connected as described.
See figure below.
Connections to the
PCB
in the control unit.
P1
Output Signals
1
DC-output signal to horn/beeper
2
Warning light signal
3
Not in use
(Do not connect)
4
Deadman output
5
STOP output, normally activated, 12/24V output
6
Not in use
(Do not connect)
7
Minus-pole/GND, for input voltage
8
Plus-pole for input voltage, 12/24V
9
Not in use
(Do not connect)
10
Not in use
(Do not connect)
SW2 see notes below,
chapter 2.2
1 Beeper warning output
2 Warning light
4 Deadman valve
5 E.M. STOP output
7 -
Power input, 12/24VDC
8 +
F1 Fuse 5A
5 Common/GND
4 Deadman handset connection
3 External STOP
1 Deadman override