User and Installation Manual for DE212-1S Wired Deadman
D
ELTA
RCS
AS
Page 12 of 17
Document: 02002
6.
T
ECHNICAL
D
ATA
This equipment is designed for failsafe operation, meeting the stringent requirements for safe operation.
It is in accordance to EU’s demands to CE
-label the equipment.
6.1
G
ENERAL
S
PECIFICATION
* Temperature Range:
Operational and storage: -25 to +65º C.
* Shock Resistance:
2 m free-fall on concrete floor.
* Cable
Coiled, 14m length fully stretched. 2 cores, cross area 0,75mm2.
6.2
C
ONTROL UNIT
,
CU212-1S
* Power Supply:
11 to 35 VDC. Voltage above 35VDC shuts down the receiver.
* Power Consumption:
Standby: 22 mA.
* Outputs:
Semiconductor output. Temperature and overload protected. Output voltage
is equal to power input; 12/24 VDC. Each output, max 3,5A
total load, 5A. Fused inside by 5A slow blow Auto fuse.
* Deadman output. Active when deadman switch is operated.
* Warning light output, active during operation of the deadman
* Beeper warning output
* STOP output. When control unit is powered, this output is active, output
is12/24V. When STOP is detected, this output is switched off.
* Optional inputs
*The CU212-1S is programmed to operate with or without a none failsafe
handswitch. To select a none failsafe handswitch, set SW2-1 to OFF. See
chapter 2.
* Deadman override, low input activates the override function
* External STOP, low input actives STOP of deadman function.
* Connections:
Screw terminal on PCB connector.
* Indicators:
Green light diode that indicates power on.
Yellow light diode that indicates active deadman.
* Housing:
ABS polycarbonate, class IP52.
* Dimensions:
L:160 mm, W: 80 mm, D: 60 mm.
* Weight:
0.7 kg
6.3
H
ANDSWITCH
,
CB212-1S
F
AILSAFE
* Controls
Two pushbuttons; Deadman and STOP.
* Operation
Deadman push button is operated by handle.
STOP is operated when handle is opened and STOP button pushed.
* Connections
Screw terminals on PCB inside housing.
* Housing:
Polyamid 6, class IP65.
* Dimensions:
Length: 170 mm, diameter: 40 mm.
* Weight:
0.3 kg