Chapter 14 PLC Function
|
C200 Series
14-2
14.1 PLC Overview
14.1.1 Introduction
The built in PLC function in C2000 allows following commands: WPLSoft, basic commands and
application commands; the operation methods are the same as Delta DVPPLC series. Other than
that, CANopen master provides 8 stations for synchronous control and 126 asynchronous controls.
NO TE
In C2000, CANopen master synchronous control complies with DS402 standard and supports homing mode, speed mode,
torque mode and point to point control mode; CANopen slave supports two control modes, speed mode and torque mode.
14.1.2 Ladder Diagram Editor – WPLSoft
WPLSoft is a program editor of Delta DVP-PLC series and C200 series for WINDOWS. Besides
general PLC program planning and general WINDOWS editing functions, such as cut, paste, copy,
multi-windows, WPLSoft also provides various Chinese/English comment editing and other special
functions (e.g. register editing, settings, the data readout, the file saving, and contacts monitor and
set, etc.).
Following is the system requirement for WPLSoft:
Item
System Requirement
Operation System
Windows 95/98/2000/NT/ME/XP
CPU
Pentium 90 and above
Memory
16MB and above (32MB and above is recommended)
Hard Disk
Capacity: 50MB and above
CD-ROM (for installing WPLSoft)
Monitor
Resolution: 640×480, 16 colors and above,
It is recommended to set display setting of Windows to 800×600.
Mouse
General mouse or the device compatible with Windows
Printer Printer
with
Windows
driver
RS-232 port
At least one of COM1 to COM8 can be connected to PLC
Applicable Models
All Delta DVP-PLC series and C200 series