MAKING ADJUSTMENTS
The factory defaults for all settings are shown in the Quick Reference Chart below. If these are acceptable, the driver board is ready
for use. If changes are required, follow the instructions to make adjustments.
DRIVER BOARD QUICK REFERENCE CHART
Function
Description
Factory
Default Setting
Function Settings
Sensor
Sensitivity
Auto Timer
(faucet shut-off)
This setting adjusts how sensitive the faucet will be on a 10 point
scale. These are relative sensitivities and do not directly
correspond to a measured distance.
This timeout will shut off flow in the event the sensor continually
sees a target. It is not used if metering mode is set.
Sensitivity setting
5
45 seconds
1 to 10
5, 7, 10, 12, 15, 30, 45, 60, 75, 90
seconds
2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0,
9.9 minutes
Symbol
d
T
R
Rinse Cycle
If this feature is turned to an “xx” hour value, the faucet will turn
on itself after this set time from last use.
--
- (OFF), 6, 12, 18, 24, 30, 36,
42, 48 hours
r
Rinse Time
This is the amount of time you want the faucet to stay on to move
the water in the line, if the
Rinse Cycle
is made active.
10 seconds
(once enabled)
10, 20, 30, 40, 50, 60, 90 seconds
2.0, 2.5, 3.0 minutes
Metering Mode
b
Buzzer
Buzzer will annunciate during power up, calibration or to indicate
low power.
ON
ON, - (OFF)
M
This feature changes the product into a metering faucet; it will run
the full set amount of time after the user’s hands are first detected.
If this feature is enabled, the timeout setting will be ignored.
--
-- (OFF), 7, 8, 9, 10, 11, 12, 13,
14, 15, 18, 24, 30, 40, 50, 60, 90
seconds
2.0, 2.5, 3.0, 3.5, 4.0 minutes
Page 4
208623 Rev. B
w w w . s p e c s e l e c t . c o m
FOR CONTROL BOX #0