BATTERY STRENGTH INDICATOR

To check the battery strength:
 

Press and hold MODE (yellow pushbutton on left hand side).  After 5 seconds the battery strength will be displayed:

 

Ɣ

  FUL  -  Healthy

 

Ɣ

  MID  -  Average

 

Ɣ

  Lo_  -  Low Average

 

Ɣ

  bAd  -  Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on)

Page 5

208623   Rev. B

w w w . s p e c s e l e c t . c o m

To adjust settings, press and hold MODE (yellow pushbutton on left hand side) until the Function symbol appears.  Once in Adjust-
ment Mode, keep pressing MODE until desired Function is reached (see Quick Reference Table).  To change Function Setting,
press and release TOGGLE (white pushbutton on right hand side) until desired Function Setting is reached (see Quick Reference
Table).

Note:

 Controller will leave Adjustment Mode after 5 seconds of inactivity.

SENSOR SENSITIVITY (d)

Higher numbers represent a more sensitive configuration.  Higher sensitivitiy will increase the distance at which the user is detected.
The sensitivity settings are on a 10 point scale (1 - 10).  Please note that these setting values are relative values and do not 
correspond to a particular distance.

AUTO TIMER (T)

Auto Timer is a safety mode in the event the sensor continually senses a target.  In this case, the faucet will stop after the pre-
determined time period expires.

RINSE CYCLE (R)

This feature is meant to purge stagnant water from supply lines.  The faucet will turn on after the set amount of hours of inactivity 
and run the set 

Rinse Time (r)

 (see below).

RINSE TIME (r)

This feature is only active if a 

Rinse Cycle (R)

 time is chosen.  The setting determines for how long the faucet will turn on during the

Rinse Cycle (R)

.  

BUZZER (b)

For Proximity the buzzer setting does not silence the controller and sensor status annunciations.
Buzzer options are ON and -(OFF), the default setting is ON.

METERING MODE (M)

This feature changes the product into a metering faucet; it will run the full set amount of time after the user’s hands are first detected.

Note: Auto Timer (T)

 is disabled when the feature is turned on.

Function

Function

Setting

MODE

TOGGLE

If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta
Commercial Technical Services at 

1-800-387-8277.

Summary of Contents for 59-PLGHDF Series

Page 1: ...tatic per ANSI and CSA requirements However we do not recommend pressure above 80 PSI Thermal expansion or leaking pressure reducing valves may require use of expansion tanks or relief valves to ensure your system never exceeds its maximum intended pressure setting 208623 208623 208623 208623 208623 208623 208623 208623 OPTION LIST 061255A Battery Holder Square 4 AA TRANSFORMERS 060704A Transforme...

Page 2: ...Attach the sensor module to the faucet shank with the clip Ensure the clip does not contact any material other than the faucet shank STEP 6 PREPARE SINK AREA Before connecting the power clean off counter and remove all objects from the sink STEP 7a CONNECT POWER IMPORTANT ENSURE THAT WATER SUPPLY IS ON BEFORE PROCEEDING WHEN POWER IS FIRST APPLIED TO THE DRIVER BOARD THE INSTALLER MUST IMMEDIATELY...

Page 3: ...onductor undergoes The change in capacitance the ability to store an electrical charge is brought on by a 2nd conductor a human body entering the Proximity field As the human hand enters and leaves the vicinity of the electrical field around the spout the solenoid is opened and closed accordingly It is critical in the installation process that all electrical and mechanical connections be as tight ...

Page 4: ...30 45 60 75 90 seconds 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 9 9 minutes Symbol d T R Rinse Cycle If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the faucet to stay on to move the water in the line if the Rinse Cycle is made active 10 seconds once enabled 10 20...

Page 5: ...cale 1 10 Please note that these setting values are relative values and do not correspond to a particular distance AUTO TIMER T Auto Timer is a safety mode in the event the sensor continually senses a target In this case the faucet will stop after the pre determined time period expires RINSE CYCLE R This feature is meant to purge stagnant water from supply lines The faucet will turn on after the s...

Page 6: ...ly wipe the surface with a damp cloth and blot dry with a soft cloth CARE INSTRUCTIONS Proximity sensing technology works by sensing changes in the electrical field Nearby conductive materials that are electrically charged or not properly electrically grounded may interfere with the desired function of the product If the controller is unable to calibrate this is most likely due to poor isolation o...

Page 7: ...lenoid is not plugged with debris Check the incoming water supply Turned on proper pressure and volume etc Check for a pressure lock between the mixing valve and the solenoid Turn off the water supply and undo the connection to the inlet of the solenoid this will eliminate any built up pressure Then activate sensor and test fire the solenoid If after above there is no clicking sound Defective sole...

Page 8: ...O RESULTANTES ESPECIALES INDIRECTOS O PUNITIVOS RELACIONADOS CON LO MENCIONADO QUEDAN EXCLUIDOS Y NO SERÁN CUBIERTOS POR DELTA FAUCET Algunos estados no permiten limitaciones de la duración de una garantía implícita o la exclusión o limitación de daños incidentales o consecuentes de manera que las limitaciones o exclusiones arriba mencionadas puedan no aplicarse en su caso Esta garantía le otorga ...

Reviews: