Ļ
Page 3
208623 Rev. B
STEP 7b. CALIBRATION
After power is applied to the driver board, it generates 5 quick beeps 3 times which prompts the
installer to step away from the unit. During the calibration process, the water will turn ON for
several seconds then proceed to shut off. An additional 5 beeps indicates calibration is complete
and the faucet is ready to use. The cover should be secured at this time.
STEP 8. TEST FOR OPERATION
Test for operation. If OK, then close lid -
Use caution not to damage wires or components
on electronic driver board.
See Fig 7.
Secure lid using screws. If faucet leaks from spout
outlet: SHUT OFF WATER SUPPLIES. Check proper solenoid connection. Replace
solenoid if problem persists. If faucet exhibits very low flow: A) Remove and clean Spray
Outlet or B) SHUT OFF WATER SUPPLY. Clean or replace Screen Assembly (2). If unit
does not work properly, see Trouble Shooting Guide on page 9.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
Fig. 6
STEP 9. BASIC OPERATION AFTER CALIBRATION
Proximity™ sensing technology works by creating an electrical field around a conductor (the
spout) and monitoring the change in capacitance that the conductor undergoes. The change
in capacitance (the ability to store an electrical charge) is brought on by a 2nd conductor
(a human body) entering the Proximity™ field. As the human hand enters and leaves the
vicinity of the electrical field around the spout, the solenoid is opened and closed accordingly.
It is critical in the installation process that all electrical and mechanical connections be as
tight and rigid as possible, ensuring a smooth signal is carried from the driver board to the
spout, and back again.
w w w . s p e c s e l e c t . c o m
Fig. 7
Trap
jacket of
cable in
hole for
strain
relief.
NOTE:
Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.
1
2
DO NOT INSTALL
9V BATTERY
FOR SURFACE MOUNT HOUSING: CONTROL BOX #0
Fig. 5
Grounding Connector
After calibration, test the function of the product by
placing your hands within close proximity of the
spout (ensuring hands are moving as if washing
hands). The solenoid will stay open while hands
are moving, then close once hands are removed
from the sensing zone.
STEP 7a. CONNECT POWER (Cont’d)
HARDWIRE CALIBRATION (Cont’d) :
Turn on power supply for the transformer. 5 quick
beeps 3 times will be generated when power is first applied to the unit. At this stage, step back
at least 3 feet from the controller and spout in order to allow for proper calibration. Do not secure
the lid/cover until after calibration.