background image

Notice

To reduce the risk associated with property damage due to 
water leakage or fl ooding:  

• Read and follow instructions before installation and use of 

this system; 

 • Comply with all state or local plumbing codes.  

• Install on cold water lines only. 

• Protect filter from freezing. Drain filter when room temperature 

drops below 40°F (4.4°C). Do not install systems in areas where 
ambient temperatures may go above 110° F (43.3° C).

• Do not install if water pressure exceeds 125 psi (862 kPa). If your 

water pressure exceeds 80 psi,  you must install a pressure limiting 
valve. Contact a plumbing professional if you are uncertain how to 
check your water pressure. 

 • Do not install where water hammer conditions may occur. If water 

hammer conditions exist you must install a water hammer arrester. 
Contact a plumbing professional if you are uncertain how to check 
for this condition.  

• Do not install on hot water supply lines. The maximum operating 

water temperature of this filter system is 100°F (38°C).   

• Where a backfl ow prevention device is installed on a water system, 

a device for controlling pressure due to thermal expansion must be 
installed. Contact a plumbing professional if you are uncertain how 
to select/install/maintain a thermal expansion device.

• Where a booster pump is installed on a water system, you must 

maintain and inspect the attached pressure switch regularly in 
accordance with the booster pump manufacturer’s instructions.  
Contact a plumbing professional if you are uncertain how to 
maintain your booster pump system.

• Where a booster pump is installed on a water system, you must 

install an appropriate pressure relief valve. Pressure relief valve 
must be maintained and inspected every 6 months. Contact a 
plumbing professional if you are uncertain how select/install/
maintain a pressure relief valve.

• Where a booster pump is installed on a water system, you must 

install an appropriate pressure regulating valve and regulate water 
pressure to <80psi. Contact a plumbing professional if you are 
uncertain how select/install/maintain a pressure regulating valve.

• Do not install near water pipes which will be in path of a drilling tool 

when selecting the position to mount the bracket. 

 • Mount filter in such a position as to prevent it from being struck by 

other items used in the area of installation (waste baskets, etc.);  

• Ensure all tubing and fittings are secure and free of leaks.

To reduce the risk of water leakage of fl ooding, and to ensure 
optimal fi lter performance:

• Change the disposable fi lter cartridge every six months or sooner if 

you observe a noticeable reduction in water fl ow rate.

• Failure to replace the disposable fi lter cartridge at recommended 

intervals may lead to reduced fi lter performance and cracks in the 
fi lter housing, causing water leakage or fl ooding.

 • Install with the inlet and outlet ports as labeled. Make sure not to 

reverse connections.

• Allow a minimum of 2 1/2” clear space under filter to facilitate 

cartridge change. 

 • Failure to follow instructions will void warranty.  

• 

For questions or concerns, please contact Customer Service 

at 1-800-345-3358.

To reduce the risk associated with ingestion of contaminants:

• Do not use with water that is microbiologically unsafe or of unknown 

quality without adequate disinfection  before or after the system. 

To reduce the risk associated with a hazardous voltage:

• Do not install near electric wiring or piping which may be in the path of 

a drilling tool when selecting  the position to mount the filter bracket.

To reduce the risk associated with choking:  

• Do not allow children under 3 years of age to have access to small 

parts during the installation of this product.

To reduce the risk of physical injury:

• Depressurize system as shown in manual prior to cartridge removal. 

    

WARNING

SAFETY INFORMATION FOR FILTER 

Read, understand, and follow all safety information contained in these 
instructions prior to installation and use. Retain these instructions for 
future reference.

Intended use:

Delta

®

 system model professional water systems are intended for use in 

filtering drinking water in homes and has not been evaluated for other uses. 
The system is typically installed under a sink where fi ltered drinking water 
is desired,  and must be installed, operated and maintained as specified in 
the installation and use instructions.

    

WARNING

Notice

Indicates a potentially hazardous situation, 
which, if not avoided, could result in death 
or serious injury and/or property damage.

Indicates a potentially hazardous situation, 
which, if not avoided, may result in 
property damage.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

        2

76420   Rev. A

Summary of Contents for 19939F-DST Series

Page 1: ...instructions avant de d buter LIRE TOUS les avertissements ainsi que toutes les instructions de nettoyage et d entretien Model Modelo Mod le 19939F DST Series Series Seria 6 5 14 Rev A ASME A112 18 1...

Page 2: ...ilter in such a position as to prevent it from being struck by other items used in the area of installation waste baskets etc Ensure all tubing and fittings are secure and free of leaks To reduce the...

Page 3: ...rramienta de perforaci n al seleccionar la posici n para montar el soporte Instale el filtro en una posici n tal que evite que sea golpeado por otros art culos utilizados en el rea de la instalaci n c...

Page 4: ...urez vous que tous les tubes et les raccords sont mont s solidement et qu ils sont tanches Pour r duire les risques de fuite d eau ou de d g t d eau et garantir un fonctionnement optimal du filtre Rem...

Page 5: ...ue el empaque 1 en la ranura en la parte inferior de la llave de agua grifo 2 B Inserte los tubos del grifo y la espiga de montaje 3 a trav s del orificio de montaje C Instale el soporte del montaje 4...

Page 6: ...chapa chapet n 3 como se muestra B Coloque las espigas 4 del ensamble de la chapa placa debajo de la cubierta en los orificios de montaje del fregadero C Deslice los tubos y la espiga del cubo o la un...

Page 7: ...r hasta que est listo para dejar fluir el agua por las l neas Inserte la gu a de la manguera 3 en el extremo de la manguera 1 como se muestra B Deslice el ensamble de la manguera 1 por el surtidor 4 y...

Page 8: ...Deje pasar el extremo de la manguera 1 por la salida de la llave de agua grifo 2 Fije el gancho 3 sobre la manguera y la salida como se muestra Moderadamente hale hacia abajo para asegurarse que la co...

Page 9: ...contact Customer Service at 1 800 345 3358 A Piezas y materiales incluidos 1 Cartucho filtrante 2 Ensamblaje de la cabeza del filtro 3 Adaptador PEX de 3 8 x 24 4 Tornillos de montaje 2 Phillips Herr...

Page 10: ...ait un cart de 1 1 2 po entre le centre de chaque vis reportez vous la figure 1 Apr s l installation le fond du filtre 2 doit se trouver au moins 2 1 2 po du fond de l armoire pour faciliter le rempla...

Page 11: ...los tubos si es necesario Nota El di metro recomendado del doblado del tubo es de un m nimo de 8 PRECAUCI N No utilice las conexiones cortadas al largo en la instalaci n del filtro C V rifiez l empla...

Page 12: ...una vuelta adicional con una llave de tuercas NO APRIETE DEMASIADO Enlace la tuber a 7 si es muy larga Nota El di metro recomendado del doblado del tubo es de un m nimo de 8 ADVERTENCIA No use compues...

Page 13: ...e agua grifo a la conexi n de la v lvula de suministro 2 y apriete a mano Con la llave de tuercas apriete la tuerca d ndole 2 vueltas m s de si fuera apretado a mano NO APRIETE DEMASIADO Repita con la...

Page 14: ...taci n correcta resultar en desconexi n y posible da o por agua 5 Deslice la tuerca sobre la manga pl stica Con la llave de tuercas apriete la tuerca d ndole 2 vueltas m s de si fuera apretado a mano...

Page 15: ...las instrucciones apropiadas para la instalaci n y apriete otra vez Si est n ensamblado correctamente f jese si los sellos est n da ados y ordene las piezas de repuesto apropiadas B El mango del roci...

Page 16: ...a prevenir Fijando la parada de l mite de la manija opcional escaldaduras porque limita la cantidad de agua caliente en la mezcla sin embargo esta manija que limita la temperatura del agua no siempre...

Page 17: ...n la cabeza Gire el cartucho hacia la derecha en direcci n de las agujas del reloj hasta que el cartucho se detiene 5 Enjuague el cartucho nuevo por 5 minutos o con 9 galones 6 Revise el filtro y la c...

Page 18: ...ara limpiar su llave simplemente fr tela con un trapo h medo y luego s quela con una toalla suave If faucet leaks from spout outlet SHUT OFF WATER SUPPLIES Replace valve cartridge 7 When reinstalling...

Page 19: ...teur inclut a rateur RP40526 Nut Only Tuerca crou seulement RP13938 O Ring Anillo O Joint torique RP63263 Adapters 3 8 24 UNEF to 1 2 20 UN 3 8 24 UNEF to 1 2 14 NPSM Adaptadors 3 8 24 UNEF to 1 2 20...

Page 20: ...hile the testing was performed under standard laboratory conditions actual performance may vary Replacement Filter RP78702 For estimated cost of replacement elements Visit www deltafaucet com or call...

Page 21: ...Warranty on Delta Faucets In the United States and Mexico In Canada Delta Faucet Company Masco Canada Limited Plumbing Group Product Service Technical Service Centre 55 E 111th Street 350 South Edgew...

Reviews: