background image

14

 WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA that the Breez 
ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) 
years from the original date of purchase.
Limitations and Exclusions
1.   During the warranty period, a replacement for any defective product will be supplied free of charge for installation 

by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the 
troubleshooting, repair, removal, and installation service.

2.   All returns of defective parts or products must include the product model number, and must be made through an 

authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement 
products will be shipped by Delta Electronics F.O.B. shipping point.

3.   Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages 

arising out of or in connection with products use or performance, regardless of the form of action whether in 
contract, tort (including negligence), strict product liability or otherwise.

4.  The warranty does not cover if user does not comply with manufacturer’s installation manual.
5.  To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
6.   Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, 

misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, 

accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to 

Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
www.deltabreez.com

Summary of Contents for 110HLEDNL

Page 1: ...ED3 TABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions New Construction 5 Assembly Instructions Existing Construction 6 Grille In...

Page 2: ...SCRIPTION QTY Fan Body 1 Grille 1 Suspension bracket 13 318 5mm 2 Suspension bracket 13 318 5mm 2 Duct Connector 1 A B C HARDWARE CONTENTS Images are to scale X 4 X 4 X 1 Long Wood Screw 4 x 25mm Shor...

Page 3: ...ting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigerat...

Page 4: ...nit must be installed in ceiling to properly sense moisture proper sensing The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be...

Page 5: ...n insert suspension bracket I and suspension bracket II into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with nails and secu...

Page 6: ...supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and finish celling...

Page 7: ...in x 10 25 in opening for the fan body 4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in P...

Page 8: ...the wiring diagram on page 4 Reattach fan junction box cover c 7 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the w...

Page 9: ...using the short screws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Re...

Page 10: ...an the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the set point the fan will continue to run at the full speed until...

Page 11: ...in water over 140 Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Clean the grille in a sink and dry with a cloth...

Page 12: ...If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noi...

Page 13: ...UCT SPECIFICATIONS 13W LED 800 Lumens 2700K Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Model No Note Light Spec 120 60 110 14 8 0 48 10 110HLEDNL VFB110D4HLED...

Page 14: ...d Repaired or replacement products will be shipped by Delta Electronics F O B shipping point 3 Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damag...

Reviews: