See safety information before proceeding. Routine maintenance should be done at least once a year.
•  Never use solvents, thinner or harsh chemicals when cleaning the fan.
•  Do not allow water to enter the motor.
•  Do not immerse metal parts in water.
•  Do not immerse resin parts in water over 140º Fahrenheit.
  Turn off power source. Review all safety precautions.

 CARE AND MAINTENANCE

1.   To remove grille 

, squeeze springs and pull down.

2.   Clean the grille 

 in a sink and dry with a cloth.

3.   Remove dust and dirt from the fan body 

 with a vacuum 

cleaner.

4.   Dampen cloth with dust detergent and wipe the fan body 

. Then wipe dry with a clean cloth.

5.  Replace grille 

 back onto fan body 

❶ .

6.  Turn on power source to operate fan again.

1

2

1

Vacuum

cleaner

2

2

1

2

3

4

5

Summary of Contents for 110HLEDNL

Page 1: ...ED3 TABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions New Construction 5 Assembly Instructions Existing Construction 6 Grille In...

Page 2: ...SCRIPTION QTY Fan Body 1 Grille 1 Suspension bracket 13 318 5mm 2 Suspension bracket 13 318 5mm 2 Duct Connector 1 A B C HARDWARE CONTENTS Images are to scale X 4 X 4 X 1 Long Wood Screw 4 x 25mm Shor...

Page 3: ...ting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigerat...

Page 4: ...nit must be installed in ceiling to properly sense moisture proper sensing The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be...

Page 5: ...n insert suspension bracket I and suspension bracket II into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with nails and secu...

Page 6: ...supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and finish celling...

Page 7: ...in x 10 25 in opening for the fan body 4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in P...

Page 8: ...the wiring diagram on page 4 Reattach fan junction box cover c 7 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the w...

Page 9: ...using the short screws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Re...

Page 10: ...an the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the set point the fan will continue to run at the full speed until...

Page 11: ...in water over 140 Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Clean the grille in a sink and dry with a cloth...

Page 12: ...If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noi...

Page 13: ...UCT SPECIFICATIONS 13W LED 800 Lumens 2700K Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Model No Note Light Spec 120 60 110 14 8 0 48 10 110HLEDNL VFB110D4HLED...