background image

10

 GRILLE INSTALLATION

Insert the LED light connector into the fan body.

Attach grille 

 by pinching mounting springs 

a

 and 

insert into the narrow rectangular slots in fan body.

 

a

2

Celling

Grille

LED light

connector

Spring

Slots

Celling

Grille

LED light

connector

Spring

Motion sensor

connector

 OPERATION

1.   Humidity control mode: Turn the POWER switch 

on to operate at humidity control mode - the LED 
indicator will be blue. When the ambient humidity 
is higher than the user-adjustable set-point, the fan 
will run at full speed, and the LED indicator is blue. 
When the ambient humidity is lower than the set-
point, the fan will continue to run at the full speed 
until a 10- minute time delay has elapsed, and then 
will automatically change to the user-adjustable low 

2.   Full speed mode: Turn the MODE switch on to 

operate at full speed mode - the LED indicator will 
be amber.

3.   Humidity tolerance is about ±10%. The humidity 

switch may need to be adjusted regionally. Long-

as dust accumlates.

60%RH.

60

30 0

50

90

80

70

60

CFM

%RH

80

60

30 0

50

90

80

70

60

CFM

%RH

80

Humidity preset control

Low speed air 

volume preset control

Summary of Contents for 110HLEDNL

Page 1: ...ED3 TABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions New Construction 5 Assembly Instructions Existing Construction 6 Grille In...

Page 2: ...SCRIPTION QTY Fan Body 1 Grille 1 Suspension bracket 13 318 5mm 2 Suspension bracket 13 318 5mm 2 Duct Connector 1 A B C HARDWARE CONTENTS Images are to scale X 4 X 4 X 1 Long Wood Screw 4 x 25mm Shor...

Page 3: ...ting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigerat...

Page 4: ...nit must be installed in ceiling to properly sense moisture proper sensing The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be...

Page 5: ...n insert suspension bracket I and suspension bracket II into the bracket cover on the duct connector side and the back of the fan body Install the suspension brackets to the joists with nails and secu...

Page 6: ...supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and finish celling...

Page 7: ...in x 10 25 in opening for the fan body 4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in P...

Page 8: ...the wiring diagram on page 4 Reattach fan junction box cover c 7 Insert housing can into the ceiling cut out Secure the housing can from below by using 2 long wood screws through the flange into the w...

Page 9: ...using the short screws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Re...

Page 10: ...an the user adjustable set point the fan will run at full speed and the LED indicator is blue When the ambient humidity is lower than the set point the fan will continue to run at the full speed until...

Page 11: ...in water over 140 Fahrenheit Turn off power source Review all safety precautions CARE AND MAINTENANCE 1 To remove grille squeeze springs and pull down 2 Clean the grille in a sink and dry with a cloth...

Page 12: ...If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noi...

Page 13: ...UCT SPECIFICATIONS 13W LED 800 Lumens 2700K Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Model No Note Light Spec 120 60 110 14 8 0 48 10 110HLEDNL VFB110D4HLED...