PMAC-Lite Hardware Reference
24
E-Point
Descriptions
E101 – E102: Output Flag Supply Voltage Configure
E Point &
Physical Layout
Location Description
Default
E101
F1
CAUTION
The jumper setting must match the
type of driver IC, or damage to the IC
will result.
Jump pin 1 to 2 to apply +V (12V to
24V) to pin 10 of U54 (should be
ULN2803A for sink output
configuration) for AENA1-4 and
EQU1-4 flag outputs.
Jump pin 2 to 3 to apply AGND to pin
10 of U54 (should be UDN2981A for
source output configuration) for
AENA1-4 and EQU1-4 flag outputs.
1-2 Jumper
installed
E102
F1
CAUTION
The jumper setting must match the
type of driver IC, or damage to the IC
will result.
Jump pin 1 to 2 to AGND to pin 9 of
U54 (should be ULN2803A for sink
output configuration) for AENA1-4
and EQU1-4 flag outputs.
Jump pin 2 to 3 to apply +V (12V to
24V) to pin 9 of U54 (should be
UDN2981A for source output
configuration) for AENA1-4 and
EQU1-4 flag outputs.
1-2 Jumper
installed
E103: Watchdog Disable Jumper
E Point &
Physical Layout
Location Description
Default
E103
A1
Jump pin 1 to 2 to disable Watchdog
timer (for test purposes only).
Remove jumper to enable Watchdog
timer.
No jumper
installed
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com