background image

 

SPECI

F

IC

ATIONS 

LOGGING

 INTERV

A

L

 

 

1, 

5, 

10,

 3

0

 s

e

co

nd

s,

 1,

 5,

 1

0

, 30 mi

nut

es,

 o

r 1

, 2

, 4

, 1

2

 o

r 2

4

 ho

urs

, p

ro

g

ramm

abl

e f

o

ea

ch 

ch

an

nel

. R

eadi

ngs

 c

an 

al

so  

A

N

D SPEED 

 

be 

re

du

ce

d t

o

 av

erag

es

, max

ima or

 minima 

at 

th

es

e i

nterv

als. T

ypical

ly

 10 

ch

an

nel

pe

r s

e

co

nd

 in

 to

tal

.  

IN

PUT CH

A

N

NEL

S

 

 

60 

ch

an

nel

s m

a

xi

mum, d

e

pe

nd

in

on i

n

pu

t ca

rd

s i

n

st

alle

d, 

pl

us 

re

sid

ent

 di

git

a

l i

n

pu

ts

 a

nd 

2 r

e

la

y outp

u

ts

.  

 

A

n

alogue

 Inp

u

ts

 

 

STA

N

D

A

RD 

AN

AL

O

G

U

E

 

 

E

a

ch 

LA

C

1

 mu

lti

plex

e

r ca

rd 

ca

sel

e

ct

 an

al

og

ue 

in

put

s fr

om:  

CA

RD

, LA

C

 

E

ither

: 15 

ch

an

nel

s o

f d

iff

ere

nti

al v

ol

tag

es 

an

d/

or 

3-w

ire r

esi

st

an

ce

s  

 

O

r: 3

0

 c

h

an

ne

ls

 o

f sin

g

le

-e

nded

 (

co

mmon g

ro

u

nd

) v

o

ltag

es 

an

d/

or 

2-w

ire

 r

e

si

st

an

ce

s  

 

D

irec

tly

 measu

re

s v

o

ltage

s u

p

 to

 ±2

V

 or r

e

si

st

an

ce

s <

1

M

. V

o

ltag

es

 u

p to 

±5

0V

 a

nd 

cu

rr

ent

can

 b

e

 me

as

ure

d

 usi

n

g  

 

pre

ci

sio

div

ider 

or s

h

un

t re

sis

tor

moun

te

d d

ire

ctly

 o

n

 the i

n

pu

t sc

rew

 te

rmin

al

s, 

or 

on

 a

n LP

R

1

 o

r LP

R

1

V

 c

a

rd

.  

4-W

IR

E

 CA

RD

, L

F

W

 

E

a

ch LF

W

1

 ca

rd can

 h

a

nd

le

 u

p

 to

 12 bri

d

ge

, po

te

nti

o

metr

ic,

 di

ffere

n

tial 

vo

ltag

e or 2- or

 4-w

ire 

re

si

st

an

ce

 sen

so

rs

 

 

4-w

ire r

e

si

st

an

ce

 meas

ur

eme

n

ts

 v

irtual

ly

 elimina

te

 c

able 

re

si

sta

n

ce

 err

o

rs

. 4

-w

ire P

t1

00 

plat

in

um r

e

si

st

an

ce

 th

erm

o

met

e

rs

,  

 

(e.

g

. D

IN

 43

76

0/B

S

190

4 ty

pes)

 a

re 

meas

ur

ed 

ov

er -2

00 

to +

8

50

°C

. I

n

 the 

-1

7 t

o

 +5

7°C

 r

ang

of 

Lo

gg

er 

an

d  

 

P

t100

 tem

p

erat

ur

e, r

e

so

lu

tion 

of 

0.

01°C

 a

n

d a

cc

u

ra

cy

 of ±0.2°C

 ar

ob

tain

ed

.  

A

C

/DC I

NPUT C

A

RD,

 

 

E

a

ch A

C

D

1

 ca

rd 

prov

ide

s 1

5

 me

as

urem

ent

 c

h

an

ne

ls

 w

h

ich may

 be 

in

di

vi

dually

 conf

ig

ure

d

 fo

r A

C

 v

o

ltag

e (

true

 rms

), D

C

 

vo

ltage  

A

CD1 

 

(dif

fer

e

nt

ia

l),

 2-

 o

3-w

ire r

e

si

st

an

ce

. D

C

 and 

re

si

sta

n

ce

 s

p

ec

ifi

ca

tio

ns

 a

re t

he 

sam

e

 a

s f

o

LA

C

1

.  

VOLTA

G

E RE

A

D

INGS 

 

 

 

Full Scale  

Resol

u

tio

n

 

(1

bits + sign)  

 

4 r

a

ng

es

, us

er-

se

lect

ed 

 

R

ang

e 1

±4mV

  

1µV

  

 

or 

aut

o

ra

ng

ed

:  

R

ang

e 2

±32mV

  

8µV

  

 

 

R

ang

e 3

±26

2

mV

  

64µV

  

 

 

R

ang

e 4

±2.

0

97

V

  

0.5mV

  

DC A

ccur

ac

 

Logge

r t

e

mpe

ratur

e

 

 

15 

to

 2

5

°C

 -2

to

 +60°C

 

 

(ty

pical figure

 

F

u

ll s

ca

le 

er

ror

  

±0.

07% 

(0.

04%

) ±

0

.2% 

(0

.1%)  

in bra

ckets)

  

Lon

g t

e

rm 

st

abi

lity

  

±0.

25% 

(0.

02%

) o

ver 1 y

ear  

 

Differ

e

ntia

l o

ffs

et 

 

±10µV

 (3µV

±0

.0

2% ±1

2µV

 ±

0

.0

2%

  

 

N

o

ise

  

(0.

2

µV

 rms

)  

 

Inp

ut im

pe

da

nc

 

100M

 a

ppr

ox

.  

 

C

o

mmon M

o

de

 R

ang

e  

±2V

 o

r ±

1

.05V

 if

 “

+

” in

pu

t i

s c

lo

ser

 to

 lo

gg

er

 0V

 th

an

 “

-” i

n

pu

t  

 

C

o

mmon M

o

de

 R

e

je

cti

on R

a

tio  

(14

0dB

),

 o

n

 v

o

lta

ge

 r

a

nge 

1  

AC

 Ac

cu

ra

c

 

Input

 le

ve

l      

   

       

    

   Sinus

oidal s

igna

ls

      

   

    

       

  Sinus

oida

l s

igna

ls

   

    

   

    

    

    Non-

s

inus

oida

l signals

 

 

 

(mV

 ac 

rms

)   

    

       

    

   

45

-6

0 Hz,

 -20

 to

 +6

0°C    

   

       

   

65

-10

0

0 Hz 

      

    

   

    

    

   

    

      Cr

est

 fa

ct

or 1.

to 1.

 

 

0 t

o

 1

0

      

    

   

    

      

    

   Re

ad

ze

ro

 in

 th

is

 ra

ng

e  

    

     

    R

e

ad

ze

ro

 in

 th

is

 ra

ng

e  

    

   

     Re

ad

zer

o

 in

 th

is

 r

an

ge

  

 

10 

to 

50

    

    

   

    

      

    

   

±3mV

   

   

       

    

   

    

    

   

    

       

    

   

    

    

   

    

       

    

   

    

    

   

    

     max

imum ad

dit

iona

l   

   

    

    

 

50 

to 

10

0  

    

    

   

      

    

   

±0.

6

% r

e

ad

in

g ±

0

.25mV

   

    

     

    

±0

.6% 

re

adi

ng 

    

    

   

    

    

   

       

er

ror

 ±

1

.0% 

re

adi

ng 

g  

100

 to

 2

0

00

      

    

     

    

   

±0.

6

% r

e

ad

in

 

©

 2006 Delta-

T

 Devices Ltd

 

 

   

 v1.1 

 

Page 10

 

Summary of Contents for DL2e

Page 1: ...DL2e Data Logger 64 Channel Research Grade Logger with support for a comprehensive range of sensors Quick Start Guide Version 1 1 Delta T Devices Ltd ...

Page 2: ...ry pack type LBK1 Battery charger Many compatible sensors are available too many to list here Overview The DL2e can log up to 128 000 readings on up to 64 channels It has a wide choice of input cards for recording DC AC voltage resistance counts frequency and status The software is easy to use and supports most sensors GSM modems and automatic data collection is possible from remote sites It is ba...

Page 3: ...cable Cold boot Reset Stop 15 30 channel slider External power connection Power supply selection link RS232 connector Power supply links for channel 63 and 64 Ribbon cable connector blocks Terminal groups 46 60 31 45 16 30 1 15 On board thermistor switches for channel 1 Digital Channels 61 62 Warmup or Relay channels 63 64 Removable screw terminal block for channels 1 5 ...

Page 4: ...ms Dataset Viewer to inspect files containing files of logged data Dataset Import Wizard to import data into Microsoft Excel Start New DL2 Control Panel 1 Connect the DL2 to the PC s serial port using the supplied serial cable New DL2 Control Panel 2 Double click on the New DL2 Control Panel icon on your desktop 3 A DL2 Connections Properties dialog box will open Click Help for comprehensive onlin...

Page 5: ...Tutorial Kit components as shown here using the screwdriver provided 2 Plug the terminal blocks back in to the terminal panel OFF 1 2 3 Set the two slider switches UP to the ON position top right of terminal board to connect channel 1 to a thermistor on the terminal board It can be used as the cold junction reference for thermocouples 3 Set up LAC1 Input Card Open the logger and ensure that an LAC...

Page 6: ...f reports as the logger checks RAM chips installs a DEFAULT logging program and goes to sleep 5 Inspect the Sensor Readings Before logging data always check the sensors readings are OK Check readings via the DL2 keypad and LCD 1 Wait for the logger to sleep 2 Press WAKE and interrupt the General Status Report by pressing READ almost immediately General Status Report message sequence on keypad afte...

Page 7: ...supplied are 1 so readings may differ a little from the nominal values 6 Reprogram the Logger 1 On the Logger panel of the DL2 Control Panel click Retrieve to upload a copy of the existing DEFAULT program in the logger An Application Notes box also opens 2 Examine the ch 1 15 tab Each row represents a channel 3 You have to tell the logger which input card is connected to each terminal group Select...

Page 8: ...ogger 16 Check your new program name appears on the Logger panel 7 Start Logging 1 Open the DL2 Control Panel by double clicking on the My Logger icon on your desktop On the Logger panel click on Start to display the Start Logging dialog The start can be deferred until a set time or until a logic condition is met on the counter channels 61 or 62 2 Click OK to start immediately Note you can click o...

Page 9: ...settings must allow macros to run refer to Excel Help 3 Dataset Import Wizard will report that it has installed successfully and will add the Import Dataset s to the File menu 4 To Start Dataset Import Wizard Start Excel select File Import Dataset s from the menu and follow the on screen instructions 5 Look for DL2 Dataset Files of type bin hfd or dat Online Help Note that LS2Win has a detailed on...

Page 10: ...S1904 types are measured over 200 to 850 C In the 17 to 57 C range of Logger and Pt100 temperature resolution of 0 01 C and accuracy of 0 2 C are obtained AC DC INPUT CARD Each ACD1 card provides 15 measurement channels which may be individually configured for AC voltage true rms DC voltage ACD1 differential 2 or 3 wire resistance DC and resistance specifications are the same as for LAC1 VOLTAGE R...

Page 11: ...el signals Every channel can record up to 65472 counts over the logging interval RELAY OUTPUTS 2 SPDT relays for powering up sensors or for providing alarms or malfunction warnings 1A 24V rating Other Specifications PROCESSING The DL2e converts readings into engineering units using look up tables or a linear conversion y mx c User expandable OF RAW READINGS sensor library includes Delta T sensors ...

Page 12: ...esiccant Exceeding this temperature may cause the glue sealing some types of desiccant package to melt When the water has been driven off remove the capsules or bags and seal them in a plastic bag to cool down until they are ready for use Legal Notices This product uses software code It should not be used in safety critical applications or where consequential loss may occur It is the responsibilit...

Reviews: