(indices 0 to 26). The units of measurement are associated with the analog inputs with the
command ADCONVUNIT_x (x = A, B, C), see section 11.10.
11.6
A
CTIVATION OF SENSORS AND STORAGE OF MEASUREMENTS
The measure of a sensor is captured and stored only if the sensor is activated with the com-
mand SENSORCONFIG and the measure is included in the tables of storage (T1... T4) with the
command MEASUREMAP. For sensors that measure many quatities, you can store all or only
some of the quantities measured.
Command
Description
P
SENSORCONFIG
Prints the list of available sensors with their activation status
(YES=enabled, NO=disabled).
SENSORCONFIG n b
Sets the activation of the sensor number n. If b = Y, the sensor is
activated, if b = N, the sensor is disabled.
n=0
Battery voltage
n=1
Tipping bucket rain gauge
n=2
Cup Anemometer
n=3
Potentiometric Sensor (wind vane)
n=4
Analog Input A
n=5
Analog Input B
n=6
Internal Barometer
n=7
LP PYRA...S
n=8
HD9008.T17S, HD9008.T7S, HD48S07TFP
n=9
HD52.3D... wind speed sensor
n=10
HD52.3D... temperature sensor (Pt100)
n=11
HD52.3D... relative humidity sensor
n=12
HD52.3D... barometric pressure sensor
n=13
HD52.3D... solar radiation sensor (pyranometer)
n=14
Housing cover opening sensor
n=15
LP SD18.1
n=16
TP32MTT.03
n=17
HD9408.3B.1 / HD9408.3B.2
n=18
Analog Input C
n=19
Not used
n=20
HD2016
n=21
HD3910...
n=22
SDI-12 sensor with address 1
n=23
SDI-12 sensor with address 2
n=24
SDI-12 sensor with address 3
n=25
SDI-12 sensor with address 4
n=26
HD2003... wind speed sensor
n=27
HD2003... temperature sensor (Pt100)
n=28
HD2003... relative humidity sensor
n=29
HD2003... barometric pressure sensor
Note: the sensors LP PYRA S, HD9008.T17S, HD9008.T7S, HD48S07TF,
HD52.3D..., LP SD18.1, TP32MTT.03, HD9408.3B.1 / HD9408.3B.2,
HD2016, HD3910... and HD2003 are connected to the COM SENSORS
input (RS485 Modbus).
LISTEXISTINGMEASURES Prints the list of measures available. For each measurement it is
showed the corresponding sensor and the activation status of the
sensor (YES = sensor activated, NO = sensor disabled).
LISTTYPECODES
Prints the list of the types of storage available.
1=Instant Value
2=Mean Value
3=Maximum Value
4=Minimum Value
5=Total (for measures of impulsive type, eg. rainfall)