Product

 

Overview 

RN400-H2 is a WiFi-based data logger with a high-performance temperature-humidity sensor

     

 

 

 

   

 

 

 

installed. Powered by batteries, it operates in wireless settings and its waterproof and dustproof

 

 

 

   

   

 

 

 

 

 

 

 

design allows for application in a wide range of working conditions. All sensor data

is transmitted in

 

 

 

     

 

   

 

   

 

 

 

   

real-time to Tapaculo365 or any other web software. The OLED screen installed on the front allows

   

   

 

 

 

 

 

 

 

   

 

 

 

users to check data as well as the setup values, and the Micro SD card slot allows for storage of

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

the measured data as well as supports the use of RN400-H2 in WPA2-enterprise settings. F-RAM,

 

 

 

 

 

 

 

 

   

   

 

 

 

known for high durability, is used for internal memory, which allows data storage up to a maximum

 

 

 

   

 

 

 

 

 

 

 

       

 

18 days without any connection to the Internet. Moreover, as it comes with various interface

 

 

 

 

   

 

 

 

   

 

 

 

 

terminals, RN400-H2 can be linked with several devices, including the external sensors, door

 

 

 

 

 

 

 

 

 

 

 

 

 

sensors,

 

and

 

dry

 

contact. 

 

 

​​

 

Potential

 

Applications

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

Block

 

Diagram

 

 

Collect

 

sensor

 

information

 

via

 

network 

 

Build

 

an

 

integrated

 

control

 

system 

 

Build

 

an

 

industrial

 

alarm

 

system 

 

Currently-In-Use

 

Applications

 

 

Food

 

storage

 

sites(refrigerators,

 

freezers) 

 

Bio-labs 

 

Building

 

energy

 

usage

 

monitoring 

 

Medicine

 

and

 

medical

 

goods

 

storage

 

sites 

 

Semiconductor

 

production

 

lines 

 

Order

 

Number

 

 

RN400H2PS

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

 

RN400H2EX 

 

RN400H2PS-S

 

​​

 

​​

 

​​

 

​​

 

​​

 

 

RN400H2EX-S 

Summary of Contents for RN400-H2PS

Page 1: ...to check data as well as the setup values and the Micro SD card slot allows for storage of the measured data as well as supports the use of RN400 H2 in WPA2 enterprise settings F RAM known for high d...

Page 2: ...nal errors 2 Refrain from using in extreme or non supported environments This leads to shorter product lifespan and may cause breakdowns or malfunctions 3 Do not use power that exceeds the allowed vol...

Page 3: ...e Sensing Interval 1Min 5Min 10Min 1Min 5Min 10Min Sending Interval 5Min 10Min 30Min 5Min 10Min 30Min Onboard Memory F RAM 32KB F RAM 32KB External Memory Option 16GB microSD permanent logging Option...

Page 4: ...he network NO WIFI CONNECTION PRESS W FOR SETUP If the device continues to fail to connect to WiFi press W and open the configu ration settings Shows SOFT AP and ACCESS address for connection Setup of...

Page 5: ...TERY before showing the setup screen when the battery is low once WAKE UP is pressed on RN400 in Battery Saver Mode For general use Energizer MAX is recommended 2 Tapaculo365 web service supports emai...

Page 6: ...l 10 min 10 data measurements will be sent each transmission F RAM BACKUP SAMPLE SIZE per Model Type Model Data Storage Duration sensing set at 10min RN400 T2PS 1CH 27 days RN400 H2PS 2CH 18 days RN40...

Page 7: ...liminates heavy metals and microorganism contaminants including ionized virus particles 3 2 Applicable External Sensor Probes Type Model Number Cable Length Diameter Spec Accuracy Other Sensor Values...

Page 8: ...and press SET UP and press ENTER after choosing 5 CALIBRATE NTC from the screen to open the CALIBRATE NTC menu 2 Start calibration by checking the NTC temperature sensor The d value shows the OFFSET...

Page 9: ...4 1 2 Side 4 1 3 Inside the Upper Casing 4 1 4 Inside the Lower Casing PS Model...

Page 10: ...5CM and PR NTC 150CM POWER When using the contact control function connect to a DC 5 30V power supply by checking the and electrodes Batteries should be inserted when connecting to a DC power supply f...

Page 11: ...heck the SOFT AP and ACCESS address Step 2 Proceed with RN400 setup with your smart phone From the WiFi setting screen of your smart phone search for WIFI AP and select _RN400 E2E8 as shown on the RN4...

Page 12: ...es with an embedded RADIUS server Thus to access the RADIUS server an ID PASSWORD and certificate CA PEM files should be prepared Save the ca pem file on the micro SD card under cert ca pem and insert...

Page 13: ...400 E2E8 ACCESS 192 168 1 1 Enter into the mode by pressing WAKE UP ENTER and check the SOFT AP and ACCESS address Step 2 Use your smart phone to proceed with RN400 setup From the WiFi setup screen of...

Page 14: ...hows model name of product SW Version Shows the currently operating software version OTA Release Version Shows the currently operating firmware version SDCARD Inserted Micro SD card inserted yes no WI...

Page 15: ...ve the measured data Refer to separate user manual for Tapaculo365 5 3 1 When Using User HTTP Server User HTTP Server URL Host Enter Host information Port Enter Port information Checkin URL Enter Chec...

Page 16: ...rs by channel currently operated by the RN400 model 5 5 WiFi Configuration 5 5 1 When Using Personal Type Access Point Select the name of the desired wireless connection SSID Show the selected wireles...

Page 17: ...ther Settings Time Zone Screen Display Setting Time Zone Configuration Select the time zone as per the location of the device Display Time OP Mode Setup the OLED screen to show the sensor value for a...

Page 18: ...menu 1 Min Ago 9 Samples Data Transfer Shows time elapsed from the last data transmission and the amount of sample data stored for the next transmission WIFI SSID dB S menu dekist 50dB Wireless Conne...

Page 19: ...Min 4 SENDING Shows the setup data transmission interval 1Min 5Min 10Min 30Min 5 UADATE Shows the last data transmission time 6 ID Shows the ID managed by Tapaculo365 7 IP 192 168 10 13 Shows the IP a...

Page 20: ...W enter P exit 4 FACTORY RESET Reset Mode Resets the information and setting of RN400 INFO Factory Default OK MENU W enter P exit 6 CHECK SYSTEM Check System Mode When registering a channel to Tapacul...

Page 21: ...temperature from the configuration screen the 220V contact is turned ON and can control other devices POWER 5 30V When using the contact control function connect the DC 5 30V power to the terminals by...

Page 22: ...oor is closed Display EVENT DOOR OPENED PLS Close the Door EVENT DOOR CLOSED Thank You Sensor Values 99 0 0 0 7 3 DRY CONTACT Dry Contact only works when the DC power supply is connected However batte...

Page 23: ...ion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving an...