background image

H0001637

.01 GB

 

DATA EASY        

Datalogger for CONTECA heat 

meters 

7504

-

7507-7554

-

7557

 

series

 

Quick guide

 

CALEFFI S.P.A. 

Summary of Contents for DATA EASY

Page 1: ...H0001637 01 GB DATA EASY Datalogger for CONTECA heat meters 7504 7507 7554 7557 series Quick guide CALEFFI S P A...

Page 2: ...ps Number of meters supported max 250 Readout interval 15 min 60 min 6 hours 12 hours 1 day factory setting Acknowledge collisions on M Bus network Yes Devices search acquisition Via Primary and or Se...

Page 3: ...nals that may damage the device make all the necessary wiring with the terminals disconnected from the device Proceed as follows Extract the terminals from the device by pulling them outwards Clamp th...

Page 4: ...n e mails the device must be able to connect to the Internet via a LAN ADSL connection or using a modem router Connection to a LAN ADSL network Using a T568A or T568B Ethernet cable straight through o...

Page 5: ...enabled for GPRS UMTS traffic lf the operator is not in possession of a Vodafone data SIM card the router settings must be changed see extended manual In this case the operations to be carried out by...

Page 6: ...page in the main menu or by accessing the web server see DATA EASY WEB SERVER manual Start the meters search by clicking OK in correspondence with the SEARCH icon or by accessing the web server see DA...

Page 7: ...B Navigation keypad C Operating status LED D Ethernet port 1 PoE E Ethernet port 2 F RS485 Bus connector G Electric supply connector H Relay output connector 1 Normally open contact I Relay output con...

Page 8: ...e with one of the pages opens the submenus which allow the display and setting of the network parameters as shown in the figure Info Pressing OK in correspondence with the main INFO menu opens a subme...

Page 9: ...in the Devices page of the Settings menu The information given for each displayed field is as follows Device Name Shows the reference of the meter specified in Device Name of the Devices web page in...

Page 10: ...save all the meters returned by the search otherwise press ESC to quit without saving any of the meters returned by the search Settings Press OK in correspondence with the SETTINGS icon to access the...

Page 11: ...11 IDB Apartment reference Floor Unit number Serial number Occupant IDB Apartment reference Floor Unit number Serial number Occupant...

Page 12: ...12 IDB Apartment reference Floor Unit number Serial number Occupant...

Page 13: ...H0001638 01 GB DATA EASY WEB SERVER Admin User Account Manual CALEFFI S P A...

Page 14: ...3 Settings Network DynDNS 13 Settings Wired devices 14 Settings Wired devices Meters setup 14 Settings Wired devices Search setup 17 Settings Events 20 Settings Events I O Events 20 Settings Events M...

Page 15: ...ear at the bottom of the screen select Control panel Network and Sharing Center Change adapter settings in the left hand menu and select the Ethernet icon then right click the mouse and click on Prope...

Page 16: ...Web browser such as Chrome Safari or Firefox Google Chrome recommended and type the address 192 168 1 110 or the address assigned to the device When the authentication form is displayed enter the web...

Page 17: ...4 Accessing the web server The credentials for the first access are User Name admin Password admin Press the Access button to enter The Home Page is as shown in the figure...

Page 18: ...n shows the web interface version Serial number shows the device serial number Internet connection shows the Internet connection status Plant Status Status of the system Events log Contains a list of...

Page 19: ...shown with the serial number model device name description and the main value set Selecting a line corresponding to a meter will open a window showing the information in detail If shown in Red the met...

Page 20: ...Devices Shows the current status of digital inputs and outputs Click on the symbol linked to the digital output Output 1 or Output 2 to force contact opening or closing Green dot means closed contact...

Page 21: ...tems are as follows Settings System Settings System Plant master data Plant Name enter a plant name Plant Address enter the plant address Installer Name enter the installer s name Customer Name enter...

Page 22: ...rd used to change the password to access the commands on the device display The default password is 000000 Restart system allows the device to be restarted Reset to factory settings to initialize the...

Page 23: ...ading a new update the system must be connected to the Internet to use this service AFTER A SYSTEM UPDATE RELOAD THE WEB PAGE 2 Backup Restore Configuration System configuration backup tick if you wis...

Page 24: ...dress set the device static LAN address IP Gateway address set the static Gateway address of the LAN Network mask set the LAN network subnet mask Primary DNS set the primary DNS address Secondary DNS...

Page 25: ...etwork Advanced Section dedicated to the configuration of DATA EASY device advanced network configuration parameters Editing of the parameters in this section should be carried out only by a specialis...

Page 26: ...entered parameters 2 Mail communication management Enable alarms notification by email enables notification by email of the alarms present on the plant as acquired by the DATA EASY device The system...

Page 27: ...arch configuration of meters present in the plant Settings Wired devices Meters setup This section provides access to a list of saved meters The first time the device is used the section will be compl...

Page 28: ...meter Installation date shows the meter installation date Readout interval frequency of meter readouts 15 minutes 1 hour 6 hours 12 hours 1 day 1 month Primary Address shows the meter address unedita...

Page 29: ...end of day maximum and the corresponding delta o Minimum generates the value as the day minimum o Maximum generates the value as the day maximum o Average generates the value as the day average Displa...

Page 30: ...dard baud rate always consult the meter datasheet to obtain this information 1 Automatic Search We recommend always performing an automatic search using the default settings 2 Manual Search use this o...

Page 31: ...r the first description to allow identification of the meter Readout interval editable frequency of meter readouts 15 minutes 1 hour 6 hours 12 hours 1 day 1 month Serial number shows the serial numbe...

Page 32: ...19 If the meter is not recognised among those in the database choose one of the available options Press Save to add the meter To edit previously saved meters go to the Meters Setup option...

Page 33: ...by transmission of an email or by means of digital outputs O1 and O2 control of external devices Important use digital outputs O1 and O2 only to control visual or audible signalling devices The follow...

Page 34: ...ter has been selected specify the type of condition from among Maximum value condition set in accordance with the maximum value acquired by the parameter Minimum value condition set in accordance with...

Page 35: ...he same staircase or all meters on the same floor of the building The system can manage up to a maximum of 250 separate groups Each group can have from one device up to a maximum of 250 Settings Group...

Page 36: ...the devices linked to DATA EASY and already in the selected group A single device can be positioned either in the right hand box or in the left hand box using the direction arrows between the two boxe...

Page 37: ...o processing export of the data logged in DATA EASY Data Export Create report Data Export Create report Meters Select one or all of the devices present in the list To select this latter option simply...

Page 38: ...pes of file format Press the Create Report button the file will be created automatically and the name will refer to the selected dates Mouse over the newly created file and left click on it to open it...

Page 39: ...chive section The report will be generated at 08 15 AM of the current day in the case of daily planning or at 08 15 AM of the last day of the selected period in consideration To conclude the settings...

Page 40: ...account types available admin and user A user account allows read only access to the data contents An admin account allows read and edit access to all the data contents The default credentials for the...

Reviews: