NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
Set -1 to disable all the tour
groups.
tour_i<0~19>_name
string[40]
1/4
Name of the tour.
tour_i<0~19>_type
<boolean>
1/4
0 = Recorded tour
1 = Preset tour
tour_i<0~19>_speed
-5 ~ 5
1/4
Preset tour: pan and tilt speed
when moving between presets.
Recorded tour: unnecessary.
tour_i<0~19>_direction forward,backward,ra
ndom
1/4
User can choose which direction
the preset tour goes.
"forward"
: preset tour goes in
forward order.
"backward"
: preset tour goes in
backward order.
"random"
: the presets of the tour
will be recalled randomly.
* Only available when
"capability_presettourdirection"
is 1.
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0307a.
tour_i<0~19>_checklist string[512]
1/4
The indexes of preset positions,
separated by “,”
tour_i<0~19>_dwelltim
e
string[512]
1/4
Preset tour: time to wait before
moving to the next preset
position, separated by “,”
Recorded tour: number of
seconds to wait
before continuing a loop tour.
P
LEASE REFER TO
PTZ
C
ONTROL
API
7.42
UART Control
© 2020 VIVOTEK INC. All Right Reserved
236
Group:
uart
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40]
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
1/4
Enable HTTP tunnel channel to control
UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate 300,600,1200,2400,
4800,9600,19200,38
400,57600,115200
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit none,
odd,
even
4/4
For error checking.
stopbit 1,2
4/4
"1"
: One stop bit is transmitted to
indicate the end of a byte.
"2"
: Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode rs485,
rs232
4/4
RS485 or RS232.
customdrvcmd_i<0~
9>
string[128]
1/4
PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_n
ame
string[40]
1/4
Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2
Summary of Contents for Vivotek FD9189-H-V2
Page 9: ...VIVOTEK User s Manual 9 Lens IR LEDs Reset button MicroSD card slot LEDst ...
Page 13: ...VIVOTEK User s Manual 13 7 Connect the Ethernet cable to the RJ45 socket ...
Page 26: ...VIVOTEK 26 User s Manual 10 Secure the camera to wall or ceiling using the included screws ...
Page 104: ...VIVOTEK 104 User s Manual ...