- 30 -
- 31 -
EN
Technical characteristics
8
CS 2000 TYXAL+ siren alarm control unit
- Power supply: Lithium battery unit 3.6 V/26 Ah
- Class III insulation
- Consumption idle 10 μA max. /Average consumption in
use 25 mA max./Average consumption in alarm 1.4 A max.
- 10-year life depending on use. Low battery voltage: < 2.7 V
- Radio frequencies 868.95 MHz and 868.30 MHz (standard EN 300 220)
- Class 1 radio equipment (can be marketed and activated without restric-
tions)
- Wireless range: 100 to 300 metres outside, variable depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class I
- 1,000,000 possible codes
- Maximum number of associated products: 16
- Number of events recorded: 1250
- Sound level at 1 m: 109 dBA +/-2
- Tamper alarm when opened or removed
- Indoor use only
- Degree of protection: IP40 - IK06
- Operating temperature: +5°C to +40°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 176 x 268.5 x 59.5 mm
- Weight (with batteries): 900 gr.
CLS 8000 TYXAL+ simple keypad
- Power supply: Lithium battery - LS 14500 - 1 x 3.6 V/2.6 Ah
- Class III insulation
- Stand-by consumption 3 μA max.
- Average consumption in transmission mode 25 mA max.
- 10-year life depending on use
- Radio frequencies 868.95 MHz and 868.30 MHz (standard EN 300 220)
- Class 1 radio equipment (can be marketed and activated without restric-
tions)
- Wireless range: 100 to 300 metres outside, variable depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 1
- Tamper alarm when opened or removed
- Indoor use only
- Degree of protection: IP30 - IK06
- Operating temperature: +5°C to +40°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 83 x 127 x 22 mm
- Weight (with batteries): 120 gr.
DMB TYXAL+ motion detector
- Power supply: Lithium battery - LS 17500 - 3.6 V
- Class III insulation
- Stand-by consumption 5 μA max.
- Average cons. in transmission mode 26 mA max.
- 10 year battery life depending on use (refer to Chapter "Replacing the
batteries")
- Radio frequencies 868.95 MHz and 868.30 MHz (standard EN 300 220)
- Class 1 radio equipment (can be marketed and activated without restric-
tions)
- Wireless range: 100 to 300 metres outside, variable depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Tamper alarm when opened or removed
- Degree of protection: IP30 - IK04
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 67.8 x 77.3 x 45.3 mm
- Weight (with batteries): 90 gr.
TL 2000 TYXAL+ remote control
- Power supply: Lithium battery - CR2430 - 3 V
- Class III insulation
- Cons. idle 0.6 μA max. / Average cons. in use 23 mA max.
- 10-year life depending on use
- Radio frequencies 868.95 MHz and 868.30 MHz (standard EN 300 220)
- Class 1 radio equipment (can be marketed and activated without restric-
tions)
- Wireless range: 100 to 300 metres outside, variable depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Degree of protection: IP32
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 42 x 65 x 8 mm
- Weight (with batteries): 25 gr.
TYDOM 1.0 (Home automation box)
- Adaptor power supply: Input 100-240V~, 50-60 Hz, 0,3 A;
Output 5V=, 1A
- Class II insulation
- Consumption:
- Radio frequency 868.95 MHz (standard EN 300 220)
- Class 1 radio equipment (can be marketed and activated without restric-
tions)
- Wireless range: 100 to 300 metres outside, variable depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Degree of protection: IP30 - IK04
- Operating temperature: -10°C to +40°C
- Storage temperature: -20°C to +70°C
- Dimensions: 100 x 100 x 30 mm
- Weight (with batteries): 472 gr.
TYDOM 1.0 LEDs
7
Information and assistance
LED
System status
Green and
flashing
System accessible locally and remotely, user
logged in
Green on and
steady
System accessible locally and remotely
Orange and
flashing
System accessible locally, user logged in
Orange and
steady
System accessible locally
Red and steady
No allocated IP address
Diagnostic function
Briefly press the button
(viewing the LED for 10 seconds)
Yellow and
flashing
Fixed IP OK
Blue and flashing
DHCP OK / Upnp
OK
Blue and flashing
(2x)
DHCP OK / Upnp
Error
Check that the Upnp is activated on the BOX
Blue and flashing
(3x)
DHCP in progress
Check that the DHCP is activated on the BOX
Flashing red
No network connection
Check the Ethernet connection
Advanced functions
Fixed DHCP/IP
Press the button for at least 3 seconds
LED
Action
Magenta
and flashing
(slowly)
Release the button
(within 15 seconds)
It is advised to use the TYDOM application to access this function.
Delete password
Press the button for at least 15 seconds
LED
Action
Magenta
and flashing
(rapidly)
Release the button
(within 30 seconds)
RESET
Press the button for at least 30 seconds
LED
Action
System status
Release the button
- Use of DHCP
- Delete password
- Clear associations