![Delta Computer Systems VMC 186/40 Manual Download Page 11](http://html1.mh-extra.com/html/delta-computer-systems/vmc-186-40/vmc-186-40_manual_2475109011.webp)
VMC 186/40 Motion Control Module Control Parameters
11
Industrial Bus Status Word Bit Map
The axis
Status Word
contains 16 bits of information about the status of the axis. The hexadecimal table
provides an easy method to convert bit patterns to hexadecimal numbers.
F 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
E 1 1 1 0 1 1 1 0 1 1 1 0 1 1 1 0
Hexadecimal To D 1 1 0 1 1 1 0 1 1 1 0 1 1 1 0 1
Binary Conversion C 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
Table B 1 0 1 1 1 0 1 1 1 0 1 1 1 0 1 1
A 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
9 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1
8 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0
7 0 1 1 1 0 1 1 1 0 1 1 1 0 1 1 1
6 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0
5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
4 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0
3 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
2 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1 0
1 0 0 0 1 0 0 0 1 0 0 0 1 0 0 0 1
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
_______ _______ _______ _______
| |*|*|*| | | |*|*| | |*| | | | | | | |
|1|1|1|1| |1|1| | | | | | | | | | | | |
|5|4|3|2| |1|0|9|8| |7|6|5|4| |3|2|1|0|
Bit Definition |_|_|_|_| |_|_|_|_| |_|_|_|_| |_|_|_|_|
-------------- / / / / / / / / / / / / / / / /
Parameters Initialized --- 15 -/ / / / / / / / / / / / / / / /
*Lag Error ---------------- 14 --/ / / / / / / / / / / / / / /
*Lead Error --------------- 13 ---/ / / / / / / / / / / / / /
*Overdrive --------------- 12 ----/ / / / / / / / / / / / /
/ / / / / / / / / / / /
Valve Out Of Null -------- 11 ------/ / / / / / / / / / / /
**Transducer Not Responding 10 -------/ / / / / / / / / / /
*Position Overflow -------- 09 --------/ / / / / / / / / /
*Parameter Error ---------- 08 ---------/ / / / / / / / /
/ / / / / / / /
Active (axis 1 only) ----- 07 -----------/ / / / / / / /
*Stopped ------------------ 06 ------------/ / / / / / /
Decelerating ------------- 05 -------------/ / / / / /
At Requested Speed ------- 04 --------------/ / / / /
/ / / /
Accelerating ------------- 03 ----------------/ / / /
Halted ------------------- 02 -----------------/ / /
Near Command Position ---- 01 ------------------/ /
At Command Position ------ 00 -------------------/
* Can cause a halt or emergency stop if the corresponding bits are clear in the appropriate mask register.
** Will cause an emergency stop no matter what the
Estop
mask register is set to.