background image

   

 

ENGAGE   |   INFLUENCE   |   OPTIMIZE

 

 

 

Document: RDS-INS9293V, Rev. A 

   

Effective Date: May 13, 2019

 

Do not copy or distribute without written permission. Unpublished Work 

 2019 Delphi Display Systems, Inc. All rights reserved. 

Printed copies are Uncontrolled unless clearly marked as a Controlled document. User is responsible for verifying document is the current revision. 

 

 

Installation  
Instructions 

 
 

 
 

 

 

 
 
 
 
 

Endura

®

15V 

Model 9320-150 V-NET 
Order Confirmation Display 

 

Summary of Contents for Endura 15V 9320-150 V-NET

Page 1: ...itten permission Unpublished Work 2019 Delphi Display Systems Inc All rights reserved Printed copies are Uncontrolled unless clearly marked as a Controlled document User is responsible for verifying d...

Page 2: ...2 CAT5 CABLE TERMINATION AT THE DISPLAY 6 5 3 V NET TRANSMITTER INSTALLATION 10 5 4 CONNECTING POWER TO THE DISPLAY 11 6 SYSTEM TEST 12 6 1 V NET TRANSMITTER TEST 12 6 2 V NET DISPLAY TEST 12 7 TECHNI...

Page 3: ...ontrolled unless clearly marked as a Controlled document User is responsible for verifying document is the current revision 1 Introduction This document describes the installation procedures for the E...

Page 4: ...ted over standard CAT5 ethernet cable up to distances of 200 ft Additionally the health status and various system parameters of the display can be monitored via a serial connection on the V Net transm...

Page 5: ...below The V Net video transmitter is connected to the external PC or video server using the supplier VGA video cable as shown in the figure below Figure 3 System Connections 4 1 Supplied Equipment The...

Page 6: ...lay Module into the applicable mounting option utilizing the supplied mounting instructions Once the Display is installed pull the supplied CAT5E cable from the display to the location of the external...

Page 7: ...ute without written permission Unpublished Work 2019 Delphi Display Systems Inc All rights reserved Printed copies are Uncontrolled unless clearly marked as a Controlled document User is responsible f...

Page 8: ...vision Terminate the CAT5E cable using the standard 568B wiring pin out as shown in the figure below Figure 6 Standard 568B Pinout Detail To begin the process of assembling the Field Connector kit for...

Page 9: ...gure 8 Field Connector Assembly Step 2 Next untwist the wires and place them into the correct order for 568B termination Cut the length of the wires down to approx 13mm then terminate the cable with t...

Page 10: ...the back of the display until it is tight Refer to the figure below for an example of a proper connection Figure 12 Connecting the RJ45 connector to the Display 5 3 V Net Transmitter Installation Rout...

Page 11: ...the 120VAC power cable to the power input connector on the rear panel of the display as shown below Verify that the power indicator lights up Figure 14 Display Power Connection Video output signal co...

Page 12: ...can be connected to the AUX VGA OUT connector to verify video is present on the VGA IN connector 6 2 V Net Display Test With the active VGA signal connected to the transmitter verify that the V Net Di...

Page 13: ...Controlled document User is responsible for verifying document is the current revision 7 Technical Support For technical assistance please contact Delphi Display Systems Inc 3550 Hyland Avenue Costa...

Reviews: