background image

7

MAX 39 in

MIN 14 in

NOTE: As special tools are required for installation, we 

suggest you have the appliance installed by specialized 

personnel.

NOTE: 

When installing the air conditioner semi-permanently, 

you should leave a door slightly open  little as   1/2“ (1 cm)  to 
guarantee correct ventilation and room pressure.

NOTE:

 Keep the air hoses as short and free of curves as possible 

to avoid constrictions.

8

DESCRIPTION OF THE CONTROL PANEL ( Fig. C)

C1

  ON/STAND-BY button

C2

 

MODE 

selection button (conditioning, dehumidifying, fan, 

heating)

C3 

Decrease temperature/programmed operation time button

C4

  Timer button

C5 

Fan speed selection button (LOW/MED/HIGH/AUTO)

C6 

Increase temperature/programmed operation time button

C7 

Air-conditioning symbol

C8 

Dehumidifying symbol

C9 

Fan symbol

C10

  Heating symbol

C11

  Alarm symbol

C12

  Fan speed indicator 

C13 

Timer symbol

C14

  Set temperature symbol 

C15

  Time indicator

C16

  Temperature value set,  programmed delayed  ON/OFF time     

Note

After few seconds  of the control panel inactivity,  its  brightness
will be automatically reduced. 
When in stand-by after few minutes  it will be further reduced.

CONTROL PANEL

C1

C10

C2

C11

C12

C14

C13

C15

C3

C4

C8 C9

C6

C16

C7

C5

C

Summary of Contents for PACAN125HPEK

Page 1: ...eaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmos...

Page 2: ...utlet If this is not the case you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable m...

Page 3: ...or log onto our website at www delonghi com SEMI PERMANENT INSTALLATION If required your appliance can also be installed semi perma nently Fig 6 min 11 8 in min 30cm min 11 8 in min 30cm Proceed as f...

Page 4: ...onditioning dehumidifying fan heating C3 Decreasetemperature programmedoperationtimebutton C4 Timer button C5 Fan speed selection button LOW MED HIGH AUTO C6 Increase temperature programmed operation...

Page 5: ...m speed for silent operation Medium speed reduces noise levels while main taining a comfortable temperature Maximumspeed toachievethetargettempera ture as rapidly as possible the appliance automatical...

Page 6: ...ppliance into the electrical receptacle and turn the unit to standby Press the timer button C4 the timer symbol C13 and the number of hours come on Use the C6 or C3 buttons to set the number of hours...

Page 7: ...e chapter OPERATING FROM THE CON TROL PANEL to select the desired functions Press button D5 to switch the temperature display from C to F and vice versa Note This equipment has been tested and found t...

Page 8: ...ditioning Dehu midifying or Heating mode contact your localauthorizedservicecenter TIPS FOR CORRECT USE To ensure optimal results from your air conditioner follow these recommendations close the windo...

Page 9: ...water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growt...

Page 10: ...ll not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if...

Page 11: ...E given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the b...

Page 12: ...art We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or a...