9

  Maximum speed

: for maximum fan power.

  

  

HEATING MODE

 

This is ideal in spring and autumn when outdoor temperatures 
are not particularly severe.  For this mode, the appliance should 
be prepared in the same way as for air conditioning, with the 
air exhaust hose (B2) attached to enable the moisture to be dis-
charged outside. To set this mode:
•   Press repeatedly the 

MODE 

button until the heating sym-

bol is displayed.

•  Press 

+

 (C3) or 

-

 (C6) buttons to adjust the desired tem-

perature.

Note: 

• 

In this mode, fan speed is selected automatically by the ap-
pliance and cannot be set manually. 

•  When operating in very cold rooms, the appliance defreez-

es automatically, momentarily interrupting normal opera-
tion.  “ Lt “ appears on the display.  During this operation, it 
is normal for the noise made by the appliance to change. 

•  In this mode, you may have to wait a few minutes before 

the appliance starts giving out hot air. 

•  In this mode, the fan may operate for short periods, even 

though the set temperature has already been reached.

•  It may happen that the display shows “HL” alarm. In this 

case, empty the internal safety tank following the instruc-
tion in the Section “End of Season operatons”. At the end, 
press again the   button to restore the heating function.

   

   SETTING THE TIMER

The timer can be used to delay appliance start up or shutdown. 
This avoids wasting electricity by not operating the appliance 
when it is not needed.

How to program delayed start up

•  Plug the appliance into the electrical receptacle and turn 

the unit to standby.

•  Press  the timer button (C4): the timer symbol (C13) and 

 

the number of hours come on.

•  Use the 

+

 (C6) or 

(C3) buttons to set the number of hours 

delay before the appliance comes on.

•  A few second after set, the setting is memorised, the timer 

symbol is lit and the display shows that the appliance is in 

standby.

•  The appliance will start working using the mode previously 

set.  The appliance can be set to come on within the next 24 

hours.

To delete the setting, press two times the timer button (C4). The 
timer symbol (C13) switches off.

How to program delayed shutdown

•  With the air conditionier on, in every mode, it is possible to 

set the delayed shutdown.

•  Press  the Timer (C4) button: the timer symbol (C13) and 

the hours switch on.

•  Use the 

+

 (C6) or 

(C3) buttons to set the number of hours 

delay before the appliance turns off.  A few second after set, 

the setting is memorised, the timer symbol is lit and the 
display shows the current mode.

 

At the end of the set time the appliance automatically turns 
in standby mode.

To delete the setting, press two times the timer button (C4). The 

timer symbol (C13) switches off.

OPERATING FROM THE REMOTE CONTROL

USING THE REMOTE CONTROL

•  Point the remote control at the receiver (A11) on the air 

conditioner. The remote control must be no more than 16

 

ft (5 meters) away from the appliance  (without obstacles 
between the remote control and the receiver).

•  The remote control must be handled with extreme care. Do 

not drop it or expose it to direct sunlight or sources of heat.

    

NOTE: 

The remote control can be safely stored in the appropiate

compartment  A12 (see figure).

MAX 16 ft

MAX 5 meters

Summary of Contents for PACAN125HPEK

Page 1: ...eaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmos...

Page 2: ...utlet If this is not the case you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable m...

Page 3: ...or log onto our website at www delonghi com SEMI PERMANENT INSTALLATION If required your appliance can also be installed semi perma nently Fig 6 min 11 8 in min 30cm min 11 8 in min 30cm Proceed as f...

Page 4: ...onditioning dehumidifying fan heating C3 Decreasetemperature programmedoperationtimebutton C4 Timer button C5 Fan speed selection button LOW MED HIGH AUTO C6 Increase temperature programmed operation...

Page 5: ...m speed for silent operation Medium speed reduces noise levels while main taining a comfortable temperature Maximumspeed toachievethetargettempera ture as rapidly as possible the appliance automatical...

Page 6: ...ppliance into the electrical receptacle and turn the unit to standby Press the timer button C4 the timer symbol C13 and the number of hours come on Use the C6 or C3 buttons to set the number of hours...

Page 7: ...e chapter OPERATING FROM THE CON TROL PANEL to select the desired functions Press button D5 to switch the temperature display from C to F and vice versa Note This equipment has been tested and found t...

Page 8: ...ditioning Dehu midifying or Heating mode contact your localauthorizedservicecenter TIPS FOR CORRECT USE To ensure optimal results from your air conditioner follow these recommendations close the windo...

Page 9: ...water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growt...

Page 10: ...ll not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if...

Page 11: ...E given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the b...

Page 12: ...art We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or a...