CONNECTING THE FEEDER CABLE
<
Remove the two screws that hold shield A behind the oven.
<
Open the cable clamp C completely.
2
<
Insert the feeder cable (Type V105) of minimum 2.5 mm cross section
through the cable gland P.
<
Connect the phase, neutral and earth conductors to terminal B according
to Fig. 1.
The wires of this appliance must be coloured in accordance with the following
code:
GREEN AND YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured GREEN AND YELLOW must be connected to
terminal in the plug which is marked with the letter “E” or by the Earth
W
symbol or coloured GREEN or GREEN AND YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is
marked with the letter “N” or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is
marked with the letter “L” or coloured RED.
<
Pull the feeder cable and secure it with cable clamp C.
<
Re-mount shield A.
REPLACING THE POWER SUPPLY CABLE
Use the same type of power supply cable.
5
C
A
P
B
Brown
(live)
Green & Yellow
(earth)
Blue
(neutral)
Figure 1