• An SC120 holds up to 24 drives, which are numbered left to right starting from 0.
Figure 14. SC120 Drive Numbering
Identifying the Failed Hard Drive
To determine which hard drive failed, use the Dell Storage Client.
1.
Click the
Hardware
tab.
2.
In the
Hardware
tab navigation pane, select the Storage Center.
3.
In the
Hardware Alerts
area, find the hardware alert that identifies the enclosure with the failed hard
drive.
Figure 15. Hardware Alert Identifying the Enclosure with the Failed Hard Drive
4.
In the
Hardware
tab navigation pane, expand the enclosure identified in the previous step.
5.
Select
Disks
. The status of each hard drive is displayed in the
Disks
tab.
6.
Select the failed hard drive. The location of the failed hard drive is displayed in the
Disk View
tab.
20
Replacing SC100/SC120 Components