Error Code
Message Information
Action
Re-configure system to the minimum supported configuration. If
issues persists, contact support.
TMP0118
Message
The system inlet temperature is less than the lower warning
threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0119
Message
The system inlet temperature is less than the lower critical threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0120
Message
The system inlet temperature is greater than the upper warning
threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
TMP0121
Message
The system inlet temperature is greater than the upper critical
threshold.
LCD Message
System inlet <
name
> temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
VLT0204
Message
The system board <
name
> voltage is outside of the allowable range.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
120
Summary of Contents for PowerVault NX400
Page 8: ...8 ...
Page 32: ...32 ...
Page 84: ...84 ...
Page 100: ...100 ...
Page 104: ...104 ...
Page 122: ...122 ...