Error Code
Message Information
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
CPU0702
Message
CPU bus parity error detected.
LCD Message
CPU bus parity error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the
exception is external to the processor.
Action
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
CPU0703
Message
CPU bus initialization error detected.
LCD Message
CPU bus initialization error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the
exception is external to the processor.
Action
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
Getting Help
.
CPU0704
Message
CPU <
number
> machine check error detected.
LCD Message
CPU <
number
> machine check error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the
exception is external to the processor.
Action
1. Check system and operating system logs for exceptions. If no
exceptions are found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
109
Summary of Contents for PowerVault NX400
Page 8: ...8 ...
Page 32: ...32 ...
Page 84: ...84 ...
Page 100: ...100 ...
Page 104: ...104 ...
Page 122: ...122 ...