4.
Route the power and data cables through the cable routing latch of the system.
5.
Connect the power and data cables to the connectors on the system board.
Figure 47. Installing the optical drive
1.
optical drive
2.
data cable
3.
power cable
4.
release tab
Next steps
Follow the procedure listed in the After working inside your system section.
Cooling fans
Depending on your system configuration, your system can support up to four cooling fans.
NOTE: Hot swappable removal or installation of the fans is not supported.
NOTE: Each fan is listed in the management software of the system, referenced by the respective fan number. If there is
a problem with a particular fan, you can easily identify and replace the proper fan by noting down the fan numbers
provided on the cooling fans.
The following table shows the number of fans required for different system configurations:
Table 22. Number of fans based on system configuration
System configuration
Number of fans
Systems with four 3.5-inch hard drives or four 2.5-inch hard drives with adapter
3
Systems with four 3.5-inch hard drives or four 2.5-inch hard drives with adapter with PCIe riser card
4
Systems with eight 2.5-inch hard drives
4
NOTE: Ensure that you install a cooling fan blank in an empty cooling fan bracket.
85