Replacing optional internal USB memory key
Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory
key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
Steps
1
Locate the USB port or USB memory key on the system board.
2
If installed, remove the USB memory key from the USB port.
3
Insert the replacement USB memory key into the USB port.
Next steps
1
Follow the procedure listed in
After working inside your system
.
2
While booting, press F2 to enter
System Setup
and verify that the system detects the USB memory key.
IDSDM
Removing the optional internal dual SD module
Prerequisites
1
Follow the safety guidelines listed in
2
Follow the procedure listed in
Before working inside your system
.
3
Remove the air shroud.
NOTE:
The procedure to remove IDSDM and the BOSS M.2 card is the same.
Steps
1
Using the Phillips #2 screwdriver, loosen the retention screw that connects the internal dual SD module (IDSDM) to the system board.
2
Lift the release tab that secures the IDSDM to the system board.
3
Holding both ends of the IDSDM, lift the IDSDM out of the IDSDM/BOSS M.2 connector on the system board.
Installing and removing system components
89