Dell PowerConnect W-IAP175 Outdoor Instant Access Point
| Installation Guide
23
Figure 19
Attaching the AP to the Mounting Bracket
Grounding the W-IAP175
The grounding must be completed before powering up the W-IAP175. The resistance of grounding wire should
be less than 5 ohm and the grounding cable’s cross-section area should be no less than 6 mm.The grounding hole
is at the right side of the W-IAP175.
Figure 20
Grounding the W-IAP175
1. Peel the cover of one end of the grounding cable (green or yellow and green grounding cable with 6 mm cross-
section area) and place the bare grounding cable into the copper lug, and press firmly with the crimping pliers.
2. Fasten the copper lug to the grounding hole on the W-IAP175 with the M4 x12 bolt and external-tooth
washer.
Front
Front
AP175_04